Search results
Results from the WOW.Com Content Network
ACI Code 7.10.4.2: For cast-in-place construction, size of spirals shall not be less than 3/8 in. diameter. ACI Code 7.10.4.3: Clear spacing between spirals shall not exceed 3 in., nor be less than 1in. Section 10.9.3 adds an additional lower limit to the amount of spiral reinforcement via the volumetric spiral reinforcement ratio ρ s.
Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.
Grade beam. A grade beam or grade beam footing is a component of a building's foundation. It consists of a reinforced concrete beam that transmits the load from a bearing wall into spaced foundations such as pile caps or caissons. [1] It is used in conditions where the surface soil's load-bearing capacity is less than the anticipated design loads.
The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3] The width of the solid area around the column should be 1 ⁄ 8 of the span between columns. Its height should be the same as the ribs. [3] Diagram showing waffle slab rib and Beam Heights rule of thumb formulas.
A large number of Indian Standard (IS) codes are available that are meant for virtually every aspect of civil engineering one can think of. During one's professional life one normally uses only a handful of them depending on the nature of work they are involved in. Civil engineers engaged in construction activities of large projects usually have to refer to a good number of IS codes as such ...
The portion of the beam that is in tension may crack. The size and length of cracks is dependent on the magnitude of the bending moment and the design of the reinforcing in the beam at the point under consideration. Reinforced concrete beams are designed to crack in tension rather than in compression.
A Chinese hack compromised even more U.S. telecoms than previously known, including Charter Communications, Consolidated Communications and Windstream, the Wall Street Journal reported late on ...
Unlike an I-beam, a T-beam lacks a bottom flange, which carries savings in terms of materials, but at the loss of resistance to tensile forces. [5] T- beam designs come in many sizes, lengths and widths to suit where they are to be used (eg highway bridge, underground parking garage) and how they have to resist the tension, compression and shear stresses associated with beam bending in their ...