Search results
Results from the WOW.Com Content Network
A Rogowski coil is a toroid of wire used to measure an alternating current I(t) through a cable encircled by the toroid. The picture shows a Rogowski coil encircling a current-carrying cable. The output of the coil, v(t), is connected to a lossy integrator circuit to obtain a voltage V out (t) that is proportional to I(t).
The only lines of B flux that encircle any current are those that are inside the toroidal winding. Therefore, from Ampere's circuital law, the intensity of the B field must be zero outside the windings. [6] Fig. 3. Toroidal inductor with circumferential current. Figure 3 of this section shows the most common toroidal winding.
With the toroidal core winding technology an electric coil or winding is created by winding an electrical conductor (e.g. copper wire) through the circular ring and evenly distributing it over the circumference (Toroidal inductors and transformers, toroidal chokes). Before the winding starts, the Toroidal / Magnetic core is mounted into a ...
A magnetic flow meter (mag meter, electromagnetic flow meter) is a transducer that measures fluid flow by the voltage induced across the liquid by its flow through a magnetic field. A magnetic field is applied to the metering tube, which results in a potential difference proportional to the flow velocity perpendicular to the flux lines.
In vector control, an AC induction or synchronous motor is controlled under all operating conditions like a separately excited DC motor. [21] That is, the AC motor behaves like a DC motor in which the field flux linkage and armature flux linkage created by the respective field and armature (or torque component) currents are orthogonally aligned such that, when torque is controlled, the field ...
A TDR waveguide with exposed wires. In the waveform analysis a sensor (usually a probe) is placed in the material to be tested. The sensor contains a waveguide consisting of two, three, or more parallel wires which is connected via a coaxial cable to a voltage pulse generator which sends precisely defined voltage pulses into the sensor.
The magnetic circuit's flux that does not interlink both windings is the leakage flux corresponding to primary leakage inductance L P σ and secondary leakage inductance L S σ. Referring to Fig. 1, these leakage inductances are defined in terms of transformer winding open-circuit inductances and associated coupling coefficient or coupling ...
The switched reluctance motor (SRM) is a type of reluctance motor. Unlike brushed DC motors , power is delivered to windings in the stator (case) rather than the rotor . This simplifies mechanical design because power does not have to be delivered to the moving rotor, which eliminates the need for a commutator .