Search results
Results from the WOW.Com Content Network
Early generator interlock kits consisted of two sliding steel or plastic (depending on the brand) plates held together by three bolts and installed on the front cover of the home's breaker panel, however, some models made by Eaton (formerly Cutler-Hammer) and Siemens for panels manufactured by them install on the adjacent circuit breakers themselves and consist of a sliding arm for breakers ...
Single-wire earth return (SWER) or single-wire ground return is a single-wire transmission line which supplies single-phase electric power from an electrical grid to remote areas at lowest cost. The earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire ) to act as a ...
Similarly, the "G" suffix can denote a "ground", hence a "51G" is a time overcurrent ground relay. The "G" suffix can also mean "generator", hence an "87G" is a Generator Differential Protective Relay while an "87T" is a Transformer Differential Protective Relay.
KN2 "Krytron" switch tube, made by EG&G (about 25 mm tall) [1] The krytron is a cold-cathode gas-filled tube intended for use as a very high-speed switch , somewhat similar to the thyratron . It consists of a sealed glass tube with four electrodes .
Simplified single line diagram of a single-phase transfer switch to select either 'city' (utility) power or local generator power 3-phase Intelligent transfer switch. A transfer switch is an electrical switch that switches a load between two sources. Some transfer switches are manual, in that an operator effects the transfer by throwing a ...
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
The ground loop still exists, but the two sides of the loop are close together, so stray magnetic fields induce equal currents in both sides, which cancel out. Break in the shield Create a break in the signal cable shield conductor. [5] The break should be at the load end. This is often called ground lifting. It is the simplest solution; it ...
In a high resistance grounded distribution system, a feeder may develop a fault to ground but the system continues in operation. The faulted, but energized, feeder can be found with a ring-type current transformer collecting all the phase wires of the circuit; only the circuit containing a fault to ground will show a net unbalanced current. To ...