  2. Setra Systems - Wikipedia

    en.wikipedia.org/wiki/Setra_Systems

    Founded in 1967, Setra Systems, Inc. is a USA-based designer and manufacturer of pressure, humidity and current sensing products for the HVAC industry. In 2001, Setra was acquired by Danaher Corporation. Setra Technology Park is located in Boxborough, MA.[2]

  3. Pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Pressure_measurement

    Differential pressure is the difference in pressure between two points. Differential pressure sensors are used to measure many properties, such as pressure drops across oil filters or air filters, fluid levels (by comparing the pressure above and below the liquid) or flow rates (by measuring the change in pressure across a restriction ...

  4. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. [1] Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be taken (e.g. start the ...

  5. DP cell - Wikipedia

    en.wikipedia.org/wiki/Dp_cell

    The DP-cell will indicate the relative difference between the pressure of the vessel (container) and the atmospheric pressure. This signal is often wired to an indicator that reads out locally, or remotely in a control room, and/or as a control (or feedback) signal to a valve, pump, or other control element to maintain a set pressure, or limit ...

  6. Proportional–integral–derivative controller - Wikipedia

    en.wikipedia.org/wiki/Proportional–integral...

    Use of a depth pressure sensor alone proved inadequate, and a pendulum that measured the fore and aft pitch of the torpedo was combined with depth measurement to become the pendulum-and-hydrostat control. Pressure control provided only a proportional control that, if the control gain was too high, would become unstable and go into overshoot ...

  7. Air purge system - Wikipedia

    en.wikipedia.org/wiki/Air_purge_system

    The differential pressure trip is connected to the inlet and the outlet of the main filter of the air blower. Failure is indicated by a decrease in the differential pressure. The low-pressure trip connects to the main filter outlet. If the pressure drops below a pre-set level, the trip relay operates.

  8. Pressure switch - Wikipedia

    en.wikipedia.org/wiki/Pressure_switch

    A pressure switch is a form of switch that operates an electrical contact when a certain set fluid pressure has been reached on its input. The switch may be designed to make contact either on pressure rise or on pressure fall. Pressure switches are widely used in industry to automatically supervise and control systems that use pressurized fluids.

  9. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    Electronic Pressure-independent control valves use a flow meter or a pressure drop across an orifice to provide flow data to an actuator that works to provide the correct flow down stream. These valves offer much lower pressure requirements as a pressure regulator requires a pressure within a range to achieve operation.