Pure-tone audiometry provides ear specific thresholds, and uses frequency specific pure tones to give place specific responses, so that the configuration of a hearing loss can be identified. As pure-tone audiometry uses both air and bone conduction audiometry, the type of loss can also be identified via the air-bone gap .
Real ear measurement is the measurement of sound pressure level in a patient's ear canal developed when a hearing aid is worn. It is measured with the use of a silicone probe tube inserted in the canal connected to a microphone outside the ear and is done to verify that the hearing aid is providing suitable amplification for a patient's hearing loss. [2]
Earplugs with probes for MIRE measurements. Also referred to as F-MIRE (field microphone in real ear). This method measures attenuation by placing a small microphone inside the ear canal while hearing protection is worn. Sound pressure levels (SPL) are measured inside and outside of the ear simultaneously and used to calculate a PAR. [26]
The first research on the topic of how the ear hears different frequencies at different levels was conducted by Fletcher and Munson in 1933. Until recently, it was common to see the term Fletcher–Munson used to refer to equal-loudness contours generally, even though a re-determination was carried out by Robinson and Dadson in 1956, which became the basis for an ISO 226 standard.
Tympanometry is an objective test of middle-ear function. It is not a hearing test, but rather a measure of energy transmission through the middle ear. It is not a measure of eardrum or middle ear mobility. It is an acoustic measure, measured by a microphone, as part of the ear canal probe, inserted into the ear canal.
Measurement of the absolute hearing threshold provides some basic information about our auditory system. [4] The tools used to collect such information are called psychophysical methods. Through these, the perception of a physical stimulus (sound) and our psychological response to the sound is measured. [9]
Measurements based on psychoacoustics, such as the measurement of noise, often use a weighting filter. It is well established that human hearing is more sensitive to some frequencies than others, as demonstrated by equal-loudness contours, but it is not well appreciated that these contours vary depending on the type of sound. The measured ...
The human ear responds quite differently to clicks and bursts of random noise, and it is this difference that gave rise to the CCIR-468 weighting curve (now supported as an ITU standard), which together with quasi-peak measurement (rather than the rms measurement used with A-weighting) became widely used by broadcasters throughout Britain ...