The use of the term mass spectroscopy is now discouraged due to the possibility of confusion with light spectroscopy. [1] [8] Mass spectrometry is often abbreviated as mass-spec or simply as MS. [1] Modern techniques of mass spectrometry were devised by Arthur Jeffrey Dempster and F.W. Aston in 1918 and 1919 respectively.
A mass spectrometer is typically utilized in one of two ways: full scan or selective ion monitoring (SIM). The typical GC–MS instrument is capable of performing both functions either individually or concomitantly, depending on the setup of the particular instrument.
Both, the first mass analyzer and the collision cell are continuously exposed to ions from the source, in a time independent manner. [4] It is once the ions move into the third mass analyzer that time dependence becomes a factor. [4] The first quadrupole mass filter, Q1, is the primary m/z selector after the sample leaves the ionization source.
Inductively coupled plasma mass spectrometry (ICP-MS) is a type of mass spectrometry that uses an inductively coupled plasma to ionize the sample. It atomizes the sample and creates atomic and small polyatomic ions , which are then detected.
Sample target for a MALDI mass spectrometer. The type of a mass spectrometer most widely used with MALDI is the time-of-flight mass spectrometer (TOF), mainly due to its large mass range. The TOF measurement procedure is also ideally suited to the MALDI ionization process since the pulsed laser takes individual 'shots' rather than working in ...
Fourier-transform ion cyclotron resonance (FTICR) mass spectrometry is a high-resolution technique that can be used to determine masses with high accuracy. Many applications of FTICR-MS use this mass accuracy to help determine the composition of molecules based on accurate mass. This is possible due to the mass defect of the elements.
[4] [5] Since the early 2000s, LC–MS (or more specifically LC–MS/MS) has also begun to be used in clinical applications. [6] In addition to the liquid chromatography and mass spectrometry devices, an LC–MS system contains an interface that efficiently transfers the separated components from the LC column into the MS ion source.
Schematic of field desorption ionization with emitter at left and mass spectrometer at right. Field desorption (FD) is a method of ion formation used in mass spectrometry (MS) in which a high-potential electric field is applied to an emitter with a sharp surface, such as a razor blade, or more commonly, a filament from which tiny "whiskers" have formed.