Search results
Results from the WOW.Com Content Network
The density of quartz is around 2.65 g/cm 3 but the (dry) bulk density of a mineral soil is normally about half that density, between 1.0 and 1.6 g/cm 3. In contrast, soils rich in soil organic carbon and some friable clays tend to have lower bulk densities ( <1.0 g/cm 3 ) due to a combination of the low-density of the organic materials ...
Concrete has a very low coefficient of thermal expansion, and as it matures concrete shrinks. All concrete structures will crack to some extent, due to shrinkage and tension. Concrete which is subjected to long-duration forces is prone to creep. The density of concrete varies, but is around 2,400 kilograms per cubic metre (150 lb/cu ft). [1]
where is the void ratio, is the porosity, V V is the volume of void-space (gases and liquids), V S is the volume of solids, and V T is the total (or bulk) volume. This figure is relevant in composites , in mining (particular with regard to the properties of tailings ), and in soil science .
Aggregation involves particulate adhesion and higher resistance to compaction. Typical bulk density of sandy soil is between 1.5 and 1.7 g/cm 3. This calculates to a porosity between 0.43 and 0.36. Typical bulk density of clay soil is between 1.1 and 1.3 g/cm 3. This calculates to a porosity between 0.58 and 0.51.
The specific weight, also known as the unit weight (symbol γ, the Greek letter gamma), is a volume-specific quantity defined as the weight W divided by the volume V of a material: = / Equivalently, it may also be formulated as the product of density, ρ, and gravity acceleration, g: = Its unit of measurement in the International System of Units (SI) is newton per cubic metre (N/m 3), with ...
K D = around 10 for artificial interlocking concrete blocks; S r = (ρ r / ρ w is the relative density of rock, i.e. (ρ r / ρ w - 1) = around 1.58 for granite in sea water; ρ r and ρ w are the densities of rock and (sea)water (-) θ is the angle of revetment with the horizontal
Mass concrete is defined by American Concrete Institute Committee 207 as "any volume of concrete with dimensions large enough to require that measures be taken to cope with the generation of heat from the hydration of cement and attendant volume change to minimize cracking."
A w/c ratio higher than 0.60 is not acceptable as fresh concrete becomes "soup" [2] and leads to a higher porosity and to very poor quality hardened concrete as publicly stated by Prof. Gustave Magnel (1889-1955, Ghent University, Belgium) during an official address to American building contractors at the occasion of one of his visits in the ...