enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Purnell equation - Wikipedia

    en.wikipedia.org/wiki/Purnell_equation

    The Purnell equation is an equation used in analytical chemistry to calculate the resolution R s between two peaks in a chromatogram. [1] [2]= (′ + ′) where R s is the resolution between the two peaks

  3. Template:Chromatography - Wikipedia

    en.wikipedia.org/wiki/Template:Chromatography

    Template: Chromatography. ... Printable version; In other projects Wikidata item; Appearance. move to sidebar hide This page was last edited on 8 July 2024, at 07:46 ...

  4. Fundamental resolution equation - Wikipedia

    en.wikipedia.org/.../Fundamental_Resolution_Equation

    It means that to increase resolution of two peaks on a chromatogram, one of the three terms of the equation need to be modified. 1) N can be increased by lengthening the column (least effective, as doubling the column will get a 2 1/2 or 1.44x increase in resolution).

  5. Resolution (chromatography) - Wikipedia

    en.wikipedia.org/wiki/Resolution_(chromatography)

    Chromatographic peak resolution is given by = + where t R is the retention time and w b is the peak width at baseline. The bigger the time-difference and/or the smaller the bandwidths, the better the resolution of the compounds.

  6. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  7. Mark–Houwink equation - Wikipedia

    en.wikipedia.org/wiki/Mark–Houwink_equation

    From this equation the molecular weight of a polymer can be determined from data on the intrinsic viscosity and vice versa. The values of the Mark–Houwink parameters, a {\displaystyle a} and K {\displaystyle K} , depend on the particular polymer- solvent system as well as temperature.

  8. Isotope dilution - Wikipedia

    en.wikipedia.org/wiki/Isotope_dilution

    In a typical gas chromatography analysis, isotopic dilution can decrease the uncertainty of the measurement results from 5% to 1%. It can also be used in mass spectrometry (commonly referred to as isotopic dilution mass spectrometry or IDMS), in which the isotopic ratio can be determined with precision typically better than 0.25%.

  9. Van Deemter equation - Wikipedia

    en.wikipedia.org/wiki/Van_Deemter_equation

    The van Deemter equation is a hyperbolic function that predicts that there is an optimum velocity at which there will be the minimum variance per unit column length and, thence, a maximum efficiency. The van Deemter equation was the result of the first application of rate theory to the chromatography elution process.

  1. Related searches bulk equation for gas chromatography calculator free printable template

    chromatogram resolution chartchromatography resolution