Search results
Results from the WOW.Com Content Network
The distortion of a waveform relative to a pure sinewave can be measured either by using a THD analyzer to analyse the output wave into its constituent harmonics and noting the amplitude of each relative to the fundamental; or by cancelling out the fundamental with a notch filter and measuring the remaining signal, which will be total aggregate ...
A total harmonic distortion analyzer calculates the total harmonic content of a sinewave with some distortion, expressed as total harmonic distortion (THD). A typical application is to determine the THD of an amplifier by using a very-low-distortion sinewave input and examining the output.
A distortionmeter is a level meter with two switchable parallel circuits at the input. The first circuit measures the total signal at the output of a system. (For low distortion levels this will be almost equal to fundamental). That value is adjusted to read 100% or, equivalently, to 0 dB.
Total harmonic distortion, or THD is a common measurement of the level of harmonic distortion present in power systems. THD can be related to either current harmonics or voltage harmonics, and it is defined as the ratio of the RMS value of all harmonics to the RMS value of the fundamental component times 100%; the DC component is neglected.
Spurious-free dynamic range (SFDR) is the strength ratio of the fundamental signal to the strongest spurious signal in the output.It is also defined as a measure used to specify analog-to-digital and digital-to-analog converters (ADCs and DACs, respectively) and radio receivers.
An alternative technique, total harmonic distortion measurement, cancels out the fundamental with a notch filter and measures the total remaining signal, which is total harmonic distortion plus noise; it does not give the harmonic-by-harmonic detail of an analyser. Spectrum analyzers are also used by audio engineers to assess their work.
Typically, an amplifier's power specifications are calculated by measuring its RMS output voltage, with a continuous sine wave signal, at the onset of clipping—defined arbitrarily as a stated percentage of total harmonic distortion (THD), usually 1%, into specified load resistances. Typical loads used are 8 and 4 ohms per channel; many ...
A system may have low distortion for a steady-state signal, but not on sudden transients. In amplifiers, this problem can be traced to power supplies in some instances, to insufficient high-frequency performance or to excessive negative feedback. Related measurements are slew rate and rise time. Distortion in transient response can be hard to ...