enow.com Web Search

  1. Ads

    related to: 4-20ma signal

Search results

  1. Results from the WOW.Com Content Network
  2. Current loop - Wikipedia

    en.wikipedia.org/wiki/Current_loop

    The 420 mA convention was born in the 1950s out of the earlier highly successful 3–15 psi pneumatic control signal standard, when electronics became cheap and reliable enough to emulate the older standard electrically. The 3–15 psi standard had the same features of being able to power some remote devices, and have a "live" zero.

  3. Highway Addressable Remote Transducer Protocol - Wikipedia

    en.wikipedia.org/wiki/Highway_Addressable_Remote...

    In point-to-point mode the digital signals are overlaid on the 420 mA loop current. Both the 420 mA current and the digital signal are valid signalling protocols between the controller and measuring instrument or final control element. The polling address of the instrument is set to "0". Only one instrument can be put on each instrument ...

  4. Digital current loop interface - Wikipedia

    en.wikipedia.org/wiki/Digital_current_loop_interface

    A digital current loop uses the absence of current for high (space or break), and the presence of current in the loop for low (mark). [1] This is done to ensure that on normal conditions there is always current flowing and in the event of a line being cut the flow stops indefinitely, immediately raising the alarm of the event usually as the heavy noise of the teleprinter not being synchronized ...

  5. Control valve - Wikipedia

    en.wikipedia.org/wiki/Control_valve

    The pneumatic control signals are traditionally based on a pressure range of 3–15 psi (0.2–1.0 bar), or more commonly now, an electrical signal of 4-20mA for industry, or 0–10 V for HVAC systems. Electrical control now often includes a "Smart" communication signal superimposed on the 420 mA control current, such that the health and ...

  6. Valve actuator - Wikipedia

    en.wikipedia.org/wiki/Valve_actuator

    The limit switches signal when an end position has been reached. The torque switching measures the torque present in the valve. When exceeding a set limit, this is signaled in the same way. Actuators are often equipped with a remote position transmitter which indicates the valve position as continuous 4-20mA current or voltage signal.

  7. 50 Times People Couldn’t Believe Their Luck In Thrift Stores

    www.aol.com/weird-wonderful-thing-100-amazing...

    You’ve just stumbled upon your dream thrift store find. For a grand total of $4.99. It doesn’t happen often, but when it does, there’s only one thing to do—brag a little. And that’s ...

  8. Foundation Fieldbus - Wikipedia

    en.wikipedia.org/wiki/FOUNDATION_fieldbus

    Foundation Fieldbus was originally intended as a replacement for the 4-20 mA standard, and today it coexists alongside other technologies such as Modbus, Profibus, and Industrial Ethernet. Foundation Fieldbus today enjoys a growing installed base in many heavy process applications such as refining, petrochemicals, power generation, and even ...

  9. Sadie Sink Says It Was 'Really Difficult to Say Goodbye' to ...

    www.aol.com/sadie-sink-says-really-difficult...

    Sadie Sink is struggling to say goodbye.. While appearing on The Tonight Show starring Jimmy Fallon on Thursday, Jan. 30, the Stranger Things star, 22, opened up about the end of her time on the ...

  1. Ads

    related to: 4-20ma signal