enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    The generator is brought up to approximate synchronous speed by supplying more energy to its shaft - for example, opening the valves on a steam turbine, opening the gates on a hydraulic turbine, or increasing the fuel rack setting on a diesel engine. The field of the generator is energized and the voltage at the terminals of the generator is ...

  3. Circle diagram - Wikipedia

    en.wikipedia.org/wiki/Circle_diagram

    The circle diagram can be drawn for alternators, synchronous motors, transformers, induction motors. The Heyland diagram is an approximate representation of a circle diagram applied to induction motors, which assumes that stator input voltage, rotor resistance and rotor reactance are constant and stator resistance and core loss are zero.

  4. Alternator - Wikipedia

    en.wikipedia.org/wiki/Alternator

    The DC generator generates a small amount of electricity, just enough to excite the field coils of the connected alternator to generate electricity. A variation of this system is a type of alternator that uses direct current from a battery for initial excitation upon start-up, after which the alternator becomes self-excited.

  5. Two-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Two-phase_electric_power

    A simplified diagram of a two-phase alternator [1] Two-phase electrical power was an early 20th-century polyphase alternating current electric power distribution system. Two circuits were used, with voltage phases differing by one-quarter of a cycle, 90°. Usually circuits used four wires, two for each phase.

  6. Permanent magnet synchronous generator - Wikipedia

    en.wikipedia.org/wiki/Permanent_magnet...

    A permanent magnet synchronous generator is a generator where the excitation field is provided by a permanent magnet instead of a coil. The term synchronous refers here to the fact that the rotor and magnetic field rotate with the same speed, because the magnetic field is generated through a shaft-mounted permanent magnet mechanism, and current is induced into the stationary armature.

  7. Short circuit ratio (synchronous generator) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    Typical values of SCR for Hydro alternators may be in the range of 1 to 1.5. Conversely, the smaller the SCR, the larger is alternator's reactance (Xd), the larger is Ld. It results from small air gaps in machine design (As in Turbo generators or Cylindrical rotor Machines). Machines are tightly coupled to the grid, and their response will be fast.

  8. Synchronous impedance curve - Wikipedia

    en.wikipedia.org/wiki/Synchronous_impedance_curve

    Synchronous impedance curve (short-circuit characteristic curve), showing armature current as function of field current. The curve is obtained by rotating the generator at the rated RPM with the output terminals shorted and the output current going to 100% of the rated for the device (higher values are typically not tested to avoid overheating).

  9. Open-circuit saturation curve - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_saturation_curve

    A diagram with multiple synchronous machine curves; open-circuit saturation curve is the leftmost one The open-circuit saturation curve (also open-circuit characteristic, OCC) of a synchronous generator is a plot of the output open circuit voltage as a function of the excitation current or field.