enow.com Web Search

  1. Ad

    related to: ups kva calculation

Search results

  1. Results from the WOW.Com Content Network
  2. Uninterruptible power supply - Wikipedia

    en.wikipedia.org/wiki/Uninterruptible_power_supply

    Most UPS below one kilovolt-ampere (1 kVA) are of the line-interactive or standby variety which are usually less expensive. For large power units, dynamic uninterruptible power supplies (DUPS) are sometimes used. A synchronous motor/alternator is connected on the mains via a choke. Energy is stored in a flywheel. When the mains power fails, an ...

  3. Volt-ampere - Wikipedia

    en.wikipedia.org/wiki/Volt-ampere

    A common prefixed derived unit is "kilovolt-ampere" (symbol kVA). The VA rating is limited by the maximum permissible current, and the watt rating by the power-handling capacity of the device. When a UPS powers equipment which presents a reactive load with a low power factor, neither limit may safely be exceeded. [4]

  4. Diesel rotary uninterruptible power supply - Wikipedia

    en.wikipedia.org/wiki/Diesel_rotary...

    Most forms of uninterruptible power supply (UPS) can be either powered by battery or flywheel energy. These are ready for immediate use at the instant that the mains electricity fails, but the relatively small and finite amount of stored energy they contain makes them suitable for short periods of use, typically in the order of a few dozen minutes to a couple of hours depending on the actual load.

  5. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    The phase shift in Europe is 120°, as is the case with three-phase current. That's why we calculate 130V * √3 = 225V. A three-phase final step-down transformer is then used. One house gets phases A & B, the next house gets phase B & C, the third house gets phase A & C.

  6. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    An important property of three-phase power is that the instantaneous power available to a resistive load, = =, is constant at all times.Indeed, let = = To simplify the mathematics, we define a nondimensionalized power for intermediate calculations, =

  7. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  8. Buck–boost transformer - Wikipedia

    en.wikipedia.org/wiki/Buck–boost_transformer

    Buck–boost transformers can be used to power low voltage circuits including control, lighting circuits, or applications that require 12, 16, 24, 32 or 48 volts, consistent with the design's secondaries. The transformer is connected as an isolating transformer and the nameplate kVA rating is the transformer’s capacity. [2]

  9. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    Resistive/reactive load banks may be used for testing turbines, switchgear, rotary UPS, generators and UPS systems. They can also be used for integrated system testing of utility substation protection systems, particularly for more complex relays like distance, directional overcurrent, power directional and others.

  1. Ad

    related to: ups kva calculation