[2] Some codes require a bonding jumper to be pulled into non-metallic conduit or in electrical metallic tubing that may be exposed to corrosion or mechanical damage. In North American electrical codes, an important bonding jumper is found in main electrical panels, where the system neutral conductor is connected to earth ground. This must be ...
The ground tab is designed to be attached to the outlet faceplate screw, which is supposed to be connected to the building electrical ground. A cheater plug, AC ground lifter or three-prong/two-prong adapter is an adapter that allows a NEMA 5-15P grounding-type plug (three prongs) to connect to a NEMA 1-15R non-grounding receptacle (two slots).
Sometimes the fittings are considered sufficiently conductive to bond (electrically unite) the metal conduit to a metal junction box (thus sharing the box's ground connection); other times, grounding bushings are used which have bonding jumpers from the bushing to a grounding screw on the box.
A similar bonding jumper wire is used between the inlet and outlet of gas meters, but here the purpose is to avoid having a substantial voltage difference between the building’s grounding electrode(s) and buried natural gas lines appear across the gas meter during the brief interval when a line to ground fault is conducting before the ...
NEMA 1-15P (two-pole, no ground) and NEMA 5-15P (two-pole with ground pin) plugs are used on common domestic electrical equipment, and NEMA 5-15R is the standard 15-ampere electric receptacle (outlet) found in the United States, and under relevant national standards, in Canada (CSA C22.2 No. 42 [1]), Mexico (NMX-J-163-ANCE) and Japan (JIS C 8303).
An earthing system (UK and IEC) or grounding system (US) connects specific parts of an electric power system with the ground, typically the equipment's conductive surface, for safety and functional purposes. [1] The choice of earthing system can affect the safety and electromagnetic compatibility of the installation.
Equipotential bonding involves electrically connecting metalwork so that it is at the same voltage everywhere. Exact rules for electrical installations vary by country, locality, or supplying power company. [2] Equipotential bonding is done from where the distribution wiring enters the building to incoming water and gas services.
An outlet is defined by the NEC as "a point in the wiring system at which current is taken to utilization equipment". [1] This definition includes receptacles, lighting, motors, etc. Ordinary switches control but do not consume electricity, and therefore are not defined as outlets in this sense.