enow.com Web Search

  1. Ads

    related to: backflow test gauge calibration

Search results

  1. Results from the WOW.Com Content Network
  2. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    There is a variety of manufacturers of these gauges, but most utilize either a three-valve or a five-valve design to test the RPZD in different ways. In the UK , [ 6 ] Illinois, New York , [ 7 ] Texas , [ 8 ] and Missouri ( RsMO 10c60-11 ), the RPZD valve must be tested at least every 12 months by an accredited tester.

  3. Pressure vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Pressure_vacuum_breaker

    A pressure vacuum breaker (PVB) is a type of backflow prevention device, used to keep non-potable (or contaminated) water from entering the water supply. A PVB is similar to an atmospheric vacuum breaker (AVB), except that the PVB contains a spring-loaded poppet. This makes it acceptable for applications that are high hazard or where valves are ...

  4. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The procedure requires multiple steps, [12] to connect the gauge under test to a reference master gauge and an adjustable pressure source, to apply fluid pressure to both reference and test gauges at definite points over the span of the gauge, and to compare the readings of the two. The gauge under test may be adjusted to ensure its zero point ...

  5. Precision measurement equipment laboratory - Wikipedia

    en.wikipedia.org/wiki/Precision_Measurement...

    The technicians who work in the PMEL will often specialize in one of these sections. The K-Sections are derived from the primary function of the TMDE. This is based upon the calibration authority. Most labs have three calibration sections divided into K1/K8, K5/K6 and K3/K4 that specialize in like test equipment.

  6. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.

  7. Double check valve - Wikipedia

    en.wikipedia.org/wiki/Double_check_valve

    A dual check backflow preventer is similar to a double check valve in operation. It has two independent spring-loaded check valves. However, dual check valves usually do not include shutoff valves, may or may not be equipped with test cocks or ports, and is generally less reliable than a double check valve.

  1. Ads

    related to: backflow test gauge calibration