enow.com Web Search

  1. Ad

    related to: reducing lugs for breakers electrical wire

Search results

  1. Results from the WOW.Com Content Network
  2. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    In the United States, solid aluminum wires made with AA-8000 series aluminum alloy are allowed for 15 A or 20 A branch circuit wiring according to the National Electrical Code. [9] The terminations need to be rated for aluminum wire, which can be problematic. This is particularly a problem with wire to wire connections made with twist-on ...

  3. Bootleg ground - Wikipedia

    en.wikipedia.org/wiki/Bootleg_ground

    A receptacle with a bootleg ground. In building wiring installed with separate neutral and protective ground bonding conductors (a TN-S network), a bootleg ground (or a false ground) is a connection between the neutral side of a receptacle or light fixture and the ground lug or enclosure of the wiring device.

  4. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    In the early 1970s new aluminium wire made from one of several special alloys was introduced, and all devices – breakers, switches, receptacles, splice connectors, wire nuts, etc. — were specially designed for the purpose. These newer aluminium wires and special designs address problems with junctions between dissimilar metals, oxidation on ...

  5. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  6. Electric wire ferrule - Wikipedia

    en.wikipedia.org/wiki/Electric_wire_ferrule

    Top: wire terminating in an insulated ferrule Center: Several ferrules with colored insulation, and two uninsulated ferrules Insulated, and uninsulated ferrules. An electric wire ferrule (sometimes electric end terminal) is a metal tube crimped over stranded wire to secure the strands within a screw terminal. Electrical insulation may be ...

  7. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    For electrical installations with split-phase (three-wire single-phase) service, the neutral point of the system is at the center-tap on the secondary side of the service transformer. For larger electrical installations, such as those with polyphase service, the neutral point is usually at the common connection on the secondary side of delta ...

  8. Bonding jumper - Wikipedia

    en.wikipedia.org/wiki/Bonding_jumper

    This is done for electrical safety grounding, static electricity protection, and may also be useful for control of electromagnetic interference. For example, a control panel door may have a bonding jumper across the hinges so that the metal door is effectively connected to ground, since the hinges may not provide a reliable contact.

  9. Contact resistance - Wikipedia

    en.wikipedia.org/wiki/Contact_resistance

    It occurs at electrical connections such as switches, connectors, breakers, contacts, and measurement probes. Contact resistance values are typically small (in the microohm to milliohm range). Contact resistance values are typically small (in the microohm to milliohm range).

  1. Ad

    related to: reducing lugs for breakers electrical wire