enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Fail-safe - Wikipedia

    en.wikipedia.org/wiki/Fail-safe

    In HVAC control systems, actuators that control dampers and valves may be fail-safe, for example, to prevent coils from freezing or rooms from overheating. Older pneumatic actuators were inherently fail-safe because if the air pressure against the internal diaphragm failed, the built-in spring would push the actuator to its home position – of ...

  3. AC 25.1309-1 - Wikipedia

    en.wikipedia.org/wiki/AC_25.1309-1

    The safety objectives associated with Catastrophic Failure Conditions may be satisfied by demonstrating that: No single failure will result in a Catastrophic Failure Condition; Each Catastrophic Failure Condition is extremely improbable; and; Significant latent failures are addressed in accordance with § 25.1309(b)(4) and § 25.1309(b)(5). [10]

  4. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality .

  5. Building automation - Wikipedia

    en.wikipedia.org/wiki/Building_automation

    Analog outputs control the speed or position of a device, such as a variable frequency drive, an I-P (current to pneumatics) transducer, or a valve or damper actuator. An example is a hot water valve opening up 25% to maintain a setpoint. Another example is a variable frequency drive ramping up a motor slowly to avoid a hard start.

  6. Fault tree analysis - Wikipedia

    en.wikipedia.org/wiki/Fault_tree_analysis

    A fault tree diagram. Fault tree analysis (FTA) is a type of failure analysis in which an undesired state of a system is examined. This analysis method is mainly used in safety engineering and reliability engineering to understand how systems can fail, to identify the best ways to reduce risk and to determine (or get a feeling for) event rates of a safety accident or a particular system level ...

  7. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. [1] Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be taken (e.g. start the ...

  8. Dedicated outdoor air system - Wikipedia

    en.wikipedia.org/wiki/Dedicated_outdoor_air_system

    DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...

  9. Failure modes, effects, and diagnostic analysis - Wikipedia

    en.wikipedia.org/wiki/Failure_Modes,_Effects...

    An FMEDA can predict failure rates per defined failure modes. For Functional Safety applications the IEC 61508 failure modes (safe, dangerous, annunciation, and no effect) are used. These failure rate numbers can be converted into the alternative failure modes from the automotive functional safety standard, ISO 26262.