The following formulas can be used to calculate the volumes of solute (V solute) and solvent (V solvent) to be used: [1] = = where V total is the desired total volume, and F is the desired dilution factor number (the number in the position of F if expressed as "1/F dilution factor" or "xF dilution"). However, some solutions and mixtures take up ...
Normality is defined as the number of gram or mole equivalents of solute present in one liter of solution.The SI unit of normality is equivalents per liter (Eq/L). = where N is normality, m sol is the mass of solute in grams, EW sol is the equivalent weight of solute, and V soln is the volume of the entire solution in liters.
For most non-electrolytes dissolved in water, the van 't Hoff factor is essentially 1. For most ionic compounds dissolved in water, the van 't Hoff factor is equal to the number of discrete ions in a formula unit of the substance. This is true for ideal solutions only, as occasionally ion pairing occurs in solution. At a given instant a small ...
A serial dilution is the step-wise dilution of a substance in solution, either by using a constant dilution factor, or by using a variable factor between dilutions. If the dilution factor at each step is constant, this results in a geometric progression of the concentration in a logarithmic fashion. A ten-fold serial dilution could be 1 M, 0.1 ...
The dilution factor is multiplied by this initial concentration to determine the original concentration. Matrix effects occur even with methods such as plasma spectrometry , which have a reputation for being relatively free from interferences.
The heat of dilution can be defined from two perspectives: the differential heat and the integral heat. The differential heat of dilution is viewed on a micro scale, which is associated with the process in which a small amount of solvent is added to a large quantity of solution. The molar differential heat of dilution is thus defined as the enthalpy
In each sector, 1 x 20 μl of the appropriate dilution is dropped onto the surface of the agar and the drop allowed to spread naturally. In the original description of the method a drop from a height of 2.5 cm spread over an area of 1.5-2.0 cm. It is important to avoid touching the surface of the agar with the pipette.
To calculate phenol coefficient, the concentration of phenol at which the compound kills the test organism in 10 minutes, but not in 5 minutes, is divided by the concentration of the test compound that kills the organism under the same conditions (or, probably more common, dividing the dilution factor at which the tested substance shows ...