enow.com Web Search

  1. Ad

    related to: hankison condensate drain valve problems

Search results

  1. Results from the WOW.Com Content Network
  2. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    A sewer pipe is normally at neutral air pressure compared to the surrounding atmosphere.When a column of waste water flows through a pipe, it compresses air ahead of it in the system, creating a positive pressure that must be released so it does not push back on the waste stream and downstream traps, slow drainage, and induce potential clogs.

  3. Compressed air dryer - Wikipedia

    en.wikipedia.org/wiki/Compressed_air_dryer

    JT type dryers are units that utilize the compressed air stream as their refrigeration element. High pressure compressed air (150~175 PSI) is fed into a pressure reducing valve on top of the dryer. The output of this valve (90–120 PSI) is directed into an expansion chamber which is surrounded with porous walls.

  4. Condensate pump - Wikipedia

    en.wikipedia.org/wiki/Condensate_pump

    Note also the 30' discharge valve and actuator to the left of the pump. - Lakeview Pumping Station, Clarendon and Montrose Avenues, Chicago, Cook County, IL} A condensate pump is a specific type of pump used to pump the condensate produced in an HVAC (heating or cooling), refrigeration, condensing boiler furnace, or steam system. [1]

  5. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    It is theoretically possible that, when both valves are faulty, backflow could occur, should the reverse flow rate exceed the capacity of the relief valve. Because certain combinations of check valve failure and/or system backpressure cause the relief valve to discharge, the device must be mounted in a location where the drain will not become ...

  6. Piping and plumbing fitting - Wikipedia

    en.wikipedia.org/wiki/Piping_and_plumbing_fitting

    Valves stop (or regulate) the flow of liquids or gases. They are categorized by application, such as isolation, throttling, and non-return. Isolation valves temporarily disconnect part of a piping system to allow maintenance or repair, for example. Isolation valves are typically left in either a fully open or closed position.

  7. Talk:Condensing boiler - Wikipedia

    en.wikipedia.org/wiki/Talk:Condensing_boiler

    The condensing heat exchangers are prone to fail due to many issues, amongst them, particulate matter getting trapped in them (even with filters) and causing heat hot spots is a major problem. The condensate itself is highly acidic and causes cement in drains to crumble -so collapsing drains . No worry, call the drain man, GDP will increase.

  8. Isolation valve - Wikipedia

    en.wikipedia.org/wiki/Isolation_valve

    Isolation valves in a flare, relief or vent system must ensure that a flow path is always available to the flare or vent. These valves are secured in the open position (LO). Drain valves that connect a high pressure system to a low pressure drain system are locked in the closed position (LC) to prevent potential over-pressurisation of the drain ...

  9. Plumbing - Wikipedia

    en.wikipedia.org/wiki/Plumbing

    Roman roofs used lead in conduits and drain pipes [14] and some were also covered with lead. Lead was also used for piping and for making baths. [15] Plumbing reached its early apex in ancient Rome, which saw the introduction of expansive systems of aqueducts, tile wastewater removal, and widespread use of lead pipes.

  1. Ad

    related to: hankison condensate drain valve problems