Search results
Results from the WOW.Com Content Network
Compared to traditional solid slabs, the reduced self-weight of biaxial slabs allows for longer spans and/or reduced deck thickness. The overall mass of concrete can be reduced by 35–50% depending on the design, [ 1 ] as a consequence of reduced slab mass, as well as lower requirements for vertical structure and foundations.
Subsequently, the deck's top reinforcing steel is placed on top of the precast panels at the site, and concrete is poured over the entire assembly to achieve the final thickness of the deck. This process effectively accelerates the construction of structures by eliminating the need for costly and time-consuming field forming, and the placing of ...
The effective reinforcement ratio was determined from the maximum arching moment of resistance in a rigidly restrained concrete slab, which Rankin [21] had derived for laterally restrained concrete slabs from McDowell, McKee and Sevin's [22] arching action deformation theory for masonry walls.
An under-reinforced beam is one in which the tension capacity of the tensile reinforcement is smaller than the combined compression capacity of the concrete and the compression steel (under-reinforced at tensile face). When the reinforced concrete element is subject to increasing bending moment, the tension steel yields while the concrete does ...
Steel-reinforced slabs, typically between 100 and 500 mm thick, are most often used to construct floors and ceilings, while thinner mud slabs may be used for exterior paving (see below). [ 1 ] [ 2 ] In many domestic and industrial buildings, a thick concrete slab supported on foundations or directly on the subsoil , is used to construct the ...
Rebar (short for reinforcement bar or reinforcing bar), known when massed as reinforcing steel or steel reinforcement, [1] is a tension device added to concrete to form reinforced concrete and reinforced masonry structures to strengthen and aid the concrete under tension.
The slabs are typically 120 cm wide with standard thicknesses normally between 15 cm and 50 cm. Reinforcing steel wire rope provides bending resistance. Slabs in prestressed concrete are usually produced in lengths of up to 200 meters. The process involves extruding wet concrete along with the prestressed steel wire rope from a moving mold. The ...
Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.