Space between the structural ceiling and the dropped ceiling or under a raised floor is typically considered plenum; however, some drop-ceiling designs create a tight seal that does not allow for airflow and therefore may not be considered a plenum air-handling space. [1] [2]
Modern dropped ceilings were initially created to hide the building infrastructure, including piping, wiring, and/or ductwork, [4] by creating a plenum space above the dropped ceiling, while allowing access for repairs and inspections. Drop ceilings may also be used to hide problems, such as structural damage.
Often refers to the space between a dropped ceiling and the structural ceiling, or a raised floor and the hard floor. Distinct from ductwork as a plenum is part of the structure itself. Cable and piping within a plenum must be properly rated for its fire and smoke indices. See also: plenum chamber psychrometric
UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor diffusers), located at or near floor level within the occupied space. Air returns from the room at ceiling level or the maximum allowable height above the occupied zone. [1]
Example of a typical commercial building with the space above the drop-ceiling acting as an air-return plenum. If a fire were to start above the drop ceiling, toxic fumes would be drawn into the open-air system and potentially poison building occupants before they are aware of the fire. Date: 10 April 2024: Source
Lend a Retro Vibe. Drop ceilings get a bad rep, but they can be a great way to disguise the inner workings of a basement—and they don't always have to make a space feel like a sad office ...
Plenum cable / ˈ p l ɛ n əm / is electrical cable that is laid in the plenum spaces of buildings. In the United States , plastics used in the construction of plenum cable are regulated under the National Fire Protection Association standard NFPA 90A: Standard for the Installation of Air Conditioning and Ventilating Systems.
An interstitial space is an intermediate space located between regular-use floors, commonly located in hospitals and laboratory-type buildings to allow space for the mechanical systems of the building. By providing this space, laboratory and hospital rooms may be easily rearranged throughout their lifecycles and therefore reduce lifecycle cost.