  1. Results from the WOW.Com Content Network
  2. Bootleg ground - Wikipedia

    en.wikipedia.org/wiki/Bootleg_ground

    In addition, a fault condition to a bootleg ground will not trip a GFCI breaker, nor protect a receptacle that is wired from the load side of a GFCI receptacle. [ 2 ] Before 1996, in the United States it was common to ground the frames of large 120/240-volt permanently-connected appliances (such as a clothes dryer or oven ) to neutral conductors.

  3. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.

  4. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    RVs in the US are equipped for 120 V 30 A or 240 V 50 A service, and use a cord to connect to a receptacle at the campsite, usually on a power pedestal with one or more receptacles providing 120 V 30 A (TT30R), 240 V 50 A (14-50R), or 120 V 15/20 A (5-20R) service.

  5. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    A 120 volt combination AFCI/GFCI receptacle. Unlike circuit breakers and fuses, which only open the circuit when the current exceeds a fixed value for a fixed time, a GFCI device will interrupt electrical service when more than 4 to 6 milliamperes of current in either conductor leaks to ground.

  6. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    If a second ground fault occurs, a ground fault protection relay must trip the breaker to protect the circuit. On an HRG system, a sensing resistor is used to continuously monitor system continuity. If an open-circuit is detected (e.g., due to a broken weld on the NGR), the monitoring device will sense voltage through the sensing resistor and ...

  7. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    This practice arose from the three-wire system used to supply both 120 volt and 240 volt loads. Because these listed appliances often have components that use either 120, or both 120 and 240 volts, there is often some current on the neutral wire. This differs from the protective grounding wire, which only carries current under fault conditions.