enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  3. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    A ground fault protection relay must trip the breaker to protect the circuit before overheating of the resistor occurs. High-resistance grounding (HRG) systems use an NGR to limit the fault current to 25 A or less. They have a continuous rating, and are designed to operate with a single-ground fault.

  4. ANSI device numbers - Wikipedia

    en.wikipedia.org/wiki/ANSI_device_numbers

    64 - Ground Protective Relay; 64F - Field Ground Protection; 64R – Rotor Earth Fault; 64REF – Restricted Earth Fault Differential; 64S – Stator Earth Fault; 64S - Sub-harmonic Stator Ground Protection; 64TN - 100% Stator Ground; 65 - Governor; 66 - Notching or Jogging Device/Maximum Starting Rate/Starts per Hour/Time Between Starts

  5. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    In an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker.

  6. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    If the wrong type was used on an installation, the level of protection given could be substantially less than that intended, in particular the voltage operated type can only protect against faults or shocks to metalwork connected to the circuit ground, connected to the VO-ELCB, it cannot detect current leaving a live wire and running to ground ...

  7. Grounding transformer - Wikipedia

    en.wikipedia.org/wiki/Grounding_transformer

    Provide a relatively low-impedance path to ground, thereby maintaining the system neutral at or near ground potential. [3] Limit the magnitude of transient over voltages when restriking ground faults occur. Provide a source of ground fault current during line-to-ground faults. Permit the connection of phase-to-neutral loads when desired. [2]

  8. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    The ground loop still exists, but the two sides of the loop are close together, so stray magnetic fields induce equal currents in both sides, which cancel out. Break in the shield Create a break in the signal cable shield conductor. [5] The break should be at the load end. This is often called ground lifting. It is the simplest solution; it ...

  9. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    A ground conductor only carries significant current if there is a circuit fault that would otherwise energize exposed conductive parts and present a shock hazard. In that case, circuit protection devices may detect a fault to a grounded metal enclosure and automatically de-energize the circuit, or may provide a warning of a ground fault.