A jockey pump, also known as a pressure-maintenance pump, is a small pump connected to a fire suppression system near the fire pump and is intended to maintain pressure in a fire protection piping system. These pumps recover pressures lost from gradual, slow pressure declines in a system due to temperature changes, trapped air escapement, or ...
It documents the approved standard procedures for performing operations safely to produce goods and provide services. [2] Compliance with the operations manual will generally be considered as activity approved by the persons legally responsible for the organisation. [3] The operations manual is intended to remind employees of how to do their job.
The Essentials of Fire Fighting is the required training manual used in countless local fire departments and state/provincial training agencies in every region of the United States and Canada. Since the release of the first edition of this manual in 1978, more than 2.5 million copies of the Essentials of Fire Fighting have been distributed to ...
The fire pump was reinvented in Europe during the 16th century, reportedly used in Augsburg in 1518 and Nuremberg in 1657. A book of 1655 inventions mentions a steam engine (called a fire engine) pump used to "raise a column of water 40 feet [12.2 m]", but there was no mention of whether it was portable.
Variable Speed Fire Pump Controllers were invented and released with a UL Listing for fire pump service in 2003 by Master Control Systems, Inc. [1] [2] Paragraph 10.5.5 in the 2003 edition of NFPA-20 recognized Variable Speed as an accepted method for operating the fire pump. Then in the NFPA-20 2007 edition, section 10.10 was added to clarify ...
Example Number 3: A well or bore running at 70 degrees Celsius (158F) with an operating level of 5 metres below the intake, minus a 2 metre friction loss into pump (pipe loss), minus the NPSH R curve (say 2.4 metres) of the pre-designed pump, minus a temperature loss of 3 metres/10 feet = an NPSH A (available) of (negative) -12.4 metres.
The pump has to be primed with the fluid to be handled prior to commissioning. Two-phase mixture is pumped until the suction line has been evacuated and the fluid level has been pushed into the front suction intake chamber by atmospheric pressure. During normal pumping operation this pump works like an ordinary centrifugal pump.
Where it is necessary to raise water to a height above that to which a suction or lift pump will operate effectively (about 7 metres), or to raise the pressure so that it will exit a nozzle with a strong force, such as through a fire hose, a force pump may be used. As with a suction pump, in its manual form it relies on an operator to pump a ...