Search results
Results from the WOW.Com Content Network
A sieve analysis (or gradation test) is a practice or procedure used in geology, civil engineering, [1] and chemical engineering [2] to assess the particle size distribution (also called gradation) of a granular material by allowing the material to pass through a series of sieves of progressively smaller mesh size and weighing the amount of material that is stopped by each sieve as a fraction ...
During the test, material from the test specimen that can pass through a No. 4 sieve is mixed with solutions of calcium chloride, formaldehyde and glycerin in a cylinder. The content is then left for sedimentation. After about 20 minutes, the level of clay suspension and the sand level is read on the cylinder scale.
Soil gradation is determined by analyzing the results of a sieve analysis or a hydrometer analysis. [4] [5] In a sieve analysis, a coarse-grained soil sample is shaken through a series of woven-wire square-mesh sieves. Each sieve has successively smaller openings so particles larger than the size of each sieve are retained on the sieve.
A variety of sieve sizes are available. The boundary between sand and silt is arbitrary. According to the Unified Soil Classification System, a #4 sieve (4 openings per inch) having 4.75 mm opening size separates sand from gravel and a #200 sieve with an 0.075 mm opening separates sand from silt and clay. According to the British standard, 0. ...
Although such information contains long lists of sieve sizes, in practice sieves are normally used in series in which each member sieve is selected to pass particles approximately 1/ √ 2 smaller in diameter or 1/2 smaller in cross-sectional area than the previous sieve. For example the series 80mm, 63, 40, 31.5, 20, 16, 14, 10, 8, 6.3, 4, 2.8 ...
The test reports loss of mass to abrasion and impact, expressed as a percentage of initial sample mass. [7] Maximum acceptable loss for the base course of the road is 45%; the more demanding surface course must be 35% or less. [1] The test was developed by the city engineers of Los Angeles in the 1920s. [8]
Download as PDF; Printable version; In other projects ... test" to this page. ... page with 'A '''gradation test''', or sieve analysis, is a commonly used procedure ...
50 g of air dried coal featuring a grain size in the range between 0.6 and 1.18 mm are filled into the sample mill and a weight is put on the mill's grinding stone. After 60 rounds the grinded coal is put on a sampling sieve. Factor D equals the fraction of the coal passing through the sieve of 74 μm corresponding to 200 mesh.