A mass flow controller is designed and calibrated to control a specific type of liquid or gas at a particular range of flow rates. The MFC can be given a setpoint from 0 to 100% of its full scale range but is typically operated in the 10 to 90% of full scale where the best accuracy is achieved.
A second type is the capillary-tube type of thermal mass flow meter. Many mass flow controllers (MFC) which combine a mass flow meter, electronics and a valve are based on this design. Furthermore, a thermal mass flow meter can be built by measuring temperature differential across a silicon-based MEMS chip.
Gas volume corrector - device for calculating, summing and determining increments of gas volume, measured by gas meter if it were operating base conditions. For this purpose, uses as input the gas volume, measured by the gas meter and other parameters such as: gas pressure and temperature. It is used for the settlement of trade wholesale gas.
That is, observed temperatures above 60 °F (or the base temperature used) typically correlate with a correction factor below "1", while temperatures below 60 °F correlate with a factor above "1". This concept lies in the basis for the kinetic theory of matter and thermal expansion of matter , which states as the temperature of a substance ...
The temperature and pressure correction factors are and , so corr = / For speed the corrected value is N {\displaystyle N} corr = {\displaystyle =} N / θ {\displaystyle N/{\sqrt {\theta }}} Example : [ 17 ] An engine is running at 100% speed and 107 lb of air is entering the compressor every second, and the day conditions are 14.5 psia and 30 ...
A more accurate correction factor can be obtained using Knudsen correction. When using nitrogen gas for core plug measurements, the Klinkenberg correction is usually necessary due to the so-called Klinkenberg gas slippage effect. This takes place when the pore space approaches the mean free path of the gas
One example of standard conditions for the calculation of SCCM is = 0 °C (273.15 K) [1] and = 1.01 bar (14.72 psia) and a unity compressibility factor = 1 (i.e., an ideal gas is used for the definition of SCCM). [2] This example is for the semi-conductor-manufacturing industry.
Laminar flow conditions are present in a gas when the Reynolds number of the gas is below the critical figure. The viscosity of the fluid must be compensated for in the result. Laminar flow elements are usually constructed from a large number of parallel pipes to achieve the required flow rating.