The cataract is removed from the capsule and anterior chamber using hydroexpression [Note 3] viscoexpression, [Note 4] or more-direct mechanical methods. [4] [13] [14] The extraction of the cataract must be done with due care so as not to compromise the integrity of the tunnel; the endothelium and capsule are also vulnerable to injury.
Two main classes of cataract surgical procedures are currently in common use throughout the world: phacoemulsification, and extracapsular cataract extraction. Intracapsular cataract extraction has been superseded where the facilities for surgery under a microscope are available except for cases where the lens capsule cannot be retained, and ...
a 26 gauge needle bent twice used for incising the anterior capsule of the lens in lens extraction Wire vectis: a loop of wire attached to a stack used to extract cataract affected lenses Irrigating vectis: a small hollow instrument with a used to introduce fluid into the anterior chamber to raise its pressure to aid cataract extraction [2] Canula
A-scan ultrasound biometry, commonly referred to as an A-scan (short for Amplitude scan), uses an ultrasound instrument for diagnostic testing. [1] A-scan biometry measures the axial length (AL) of the eye prior to cataract surgery in order to assess the refractive power of the intraocular lens that will be implanted.
Requires a higher level of patient understanding and concentration compared to other visual field tests [9] Time-consuming; Learning effect: new patients improve as more tests are performed due to understanding of the test conditions. Consider the third test as the baseline result [23] Potential for artefacts (i.e. uncharacteristic vision loss ...
Intracapsular cryoextraction was the favoured form of cataract extraction from the late 1960s to the early 1980s: it consisted in using a liquid-nitrogen-cooled probe tip to freeze the encapsulated lens to the probe. This required a large incision and the cornea to be folded back and the anterior chamber to be drained.
Visual acuity with Near chart without correctors Visual acuity with eye chart at Near 15.7 inches (400 mm) and without (sc: Latin sine correctore) correctors (spectacles); Ncc is with (cc: Latin cum correctore) correctors. See Visual_acuity#Legal_definitions: VA OS Left visual acuity VA OD Right visual acuity VDU Visual display unit VF Visual field
A person taking the test covers one eye from 6 metres or 20 feet away, and reads aloud the letters of each row, beginning at the top. The smallest row that can be read accurately indicates the visual acuity in that specific eye. The symbols on an acuity chart are formally known as "optotypes". Variation of Snellen chart with another letter ...