enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Heat pump and refrigeration cycle - Wikipedia

    en.wikipedia.org/wiki/Heat_pump_and...

    At the start of the thermodynamic cycle the refrigerant enters the compressor as a low pressure and low temperature vapor. In heat pumps, this refrigerant is typically R32 refrigerant or R290 refrigerant. Then the pressure is increased and the refrigerant leaves as a higher temperature and higher pressure superheated gas.

  3. List of refrigerants - Wikipedia

    en.wikipedia.org/wiki/List_of_refrigerants

    Refrigerant concentration limit / immediately dangerous to life or health in parts per million (volume per volume) and grams per cubic meter Molecular mass in atomic mass units Normal boiling points for pure substances, bubble and dew points for zeotropic blends, or normal boiling point and azeotropic temperature for the azeotropic blends, at ...

  4. Vapor-compression refrigeration - Wikipedia

    en.wikipedia.org/wiki/Vapor-compression...

    A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.

  5. Heat pump - Wikipedia

    en.wikipedia.org/wiki/Heat_pump

    This can be achieved by cooling the liquid refrigerant after condensation. The gaseous refrigerant condenses on the heat exchange surface of the condenser. To achieve a heat flow from the gaseous flow center to the wall of the condenser, the temperature of the liquid refrigerant must be lower than the condensation temperature.

  6. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The COP of absorption chillers can be improved by adding a second or third stage. Double and triple effect chillers are significantly more efficient than single effect chillers, and can surpass a COP of 1. They require higher pressure and higher temperature steam, but this is still a relatively small 10 pounds of steam per hour per ton of cooling.

  7. Critical point (thermodynamics) - Wikipedia

    en.wikipedia.org/wiki/Critical_point...

    The liquid–liquid critical point of a solution, which occurs at the critical solution temperature, occurs at the limit of the two-phase region of the phase diagram. In other words, it is the point at which an infinitesimal change in some thermodynamic variable (such as temperature or pressure) leads to separation of the mixture into two ...

  8. Cascade refrigeration - Wikipedia

    en.wikipedia.org/wiki/Cascade_refrigeration

    A two-cycle cascade refrigeration process schematic diagram. A cascade refrigeration cycle is a multi-stage thermodynamic cycle. An example two-stage process is shown at right. (Bottom on mobile) The cascade cycle is often employed for devices such as ULT freezers. [1]

  9. 1,1,1,2-Tetrafluoroethane - Wikipedia

    en.wikipedia.org/wiki/1,1,1,2-Tetrafluoroethane

    1,1,1,2-Tetrafluoroethane is a non-flammable gas used primarily as a "high-temperature" refrigerant for domestic refrigeration and automobile air conditioners. These devices began using 1,1,1,2-tetrafluoroethane in the early 1990s as a replacement for the more environmentally harmful R-12. Retrofit kits are available to convert units that were ...