  1. Results from the WOW.Com Content Network
  2. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    The resistance of copper wire is approximately ⁠ 1 ohms / 1000 feet ⁠ for 10 AWG, ⁠ 10 ohms / 1000 feet ⁠ for 20 AWG, ⁠ 100 ohms / 1000 feet ⁠ for 30 AWG, and so on. [ 5 ] : 27 Because aluminum wire has a conductivity of approximately 61% of copper, an aluminum wire has nearly the same resistance as a copper wire that is two sizes ...

  3. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Also, the size of the aluminum wire needs to be larger compared to copper wire used for the same circuit due to the increased resistance of the aluminum alloys. For example, a 15 A branch circuit supplying standard lighting fixtures can be installed with either #14 AWG copper building wire or #12 AWG aluminum building wire according to the NEC ...

  4. Wire gauge - Wikipedia

    en.wikipedia.org/wiki/Wire_gauge

    IEC 60228, the metric wire-size standard used in most parts of the world. Circular mil, Electrical industry standard for wires larger than 4/0. American Wire Gauge (AWG), used primarily in the US and Canada; Standard Wire Gauge (SWG), the British imperial standard BS3737; Jewelry wire gauge; Body jewelry sizes

  5. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    For example, the United States National Electrical Code, Table 310.15(B)(16), specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30 °C, the conductor surface temperature allowed to be 75 °C. A single insulated conductor ...

  6. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  7. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    For instance, instead of 14 AWG (American wire gauge) copper wire, aluminium wiring would need to be 12 AWG on a typical 15 ampere lighting circuit, though local building codes vary. Solid aluminium conductors were originally made in the 1960s from a utility-grade aluminium alloy that had undesirable properties for a building wire, and were ...

  8. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  9. Talk:Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Talk:Aluminum_building_wiring

    No, that's not the case. Aluminum conductors are required to be larger for the same current rating. Equivalently, the same size aluminum wire carries less current than a copper wire. Here's what Rule 240.4(D) says for maximum overcurrent size: 14 AWG - 15 amps copper, no rating for aluminum; 12 AWG - 20 A Cu, 15 A for Al; 10 AWG - 30 A Cu, 25 A ...