Ads
related to: thermocouple calculation formula
Search results
Results from the WOW.Com Content Network
A thermocouple, also known as a "thermoelectrical thermometer", is an electrical device consisting of two dissimilar electrical conductors forming an electrical junction.A thermocouple produces a temperature-dependent voltage as a result of the Seebeck effect, and this voltage can be interpreted to measure temperature.
In thermocouples the Seebeck effect is used to measure temperatures, and for accuracy it is desirable to use materials with a Seebeck coefficient that is stable over time. Physically, the magnitude and sign of the Seebeck coefficient can be approximately understood as being given by the entropy per unit charge carried by electrical currents in ...
Thermoelectric sorting functions similarly to a thermocouple but involves an unknown material instead of an unknown temperature: a metallic probe of known composition is kept at a constant known temperature and held in contact with the unknown sample that is locally heated to the probe temperature, thereby providing an approximate measurement ...
The efficiency of a thermoelectric device for electricity generation is given by , defined as =.. The maximum efficiency of a thermoelectric device is typically described in terms of its device figure of merit where the maximum device efficiency is approximately given by [7] = + ¯ + ¯ +, where is the fixed temperature at the hot junction, is the fixed temperature at the surface being cooled ...
Vertical design has thermocouples arranged vertically between the hot and cool plates, leading to high integration of thermocouples as well as a high output voltage, making this design the most widely-used design commercially. The mixed design has the thermocouples arranged laterally on the substrate while the heat flow is vertical between plates.
The two top thermocouple junctions are at temperature T 1 while the two bottom thermocouple junctions are at temperature T 2. The output voltage from the thermopile, ΔV , is directly proportional to the temperature differential, ΔT or T 1 - T 2 , across the thermal resistance layer and number of thermocouple junction pairs.
The Callendar–Van Dusen equation is an equation that describes the relationship between resistance (R) and temperature (T) of platinum resistance thermometers (RTD).. As commonly used for commercial applications of RTD thermometers, the relationship between resistance and temperature is given by the following equations.
The Steinhart–Hart equation is a model relating the varying electrical resistance of a semiconductor to its varying temperatures.The equation is = + + (), where is the temperature (in kelvins),
Ads
related to: thermocouple calculation formula