  1. Results from the WOW.Com Content Network
  2. Nested RAID levels - Wikipedia

    en.wikipedia.org/wiki/Nested_RAID_levels

    One drive from each of the RAID 5 sets could fail without loss of data; for example, a RAID 50 configuration including three RAID 5 sets can tolerate three maximum potential simultaneous drive failures (but only one per RAID 5 set). Because the reliability of the system depends on quick replacement of the bad drive so the array can rebuild, it ...

  3. Standard RAID levels - Wikipedia

    en.wikipedia.org/wiki/Standard_RAID_levels

    Diagram of a RAID 1 setup. RAID 1 consists of an exact copy (or mirror) of a set of data on two or more disks; a classic RAID 1 mirrored pair contains two disks.This configuration offers no parity, striping, or spanning of disk space across multiple disks, since the data is mirrored on all disks belonging to the array, and the array can only be as big as the smallest member disk.

  4. RAID - Wikipedia

    en.wikipedia.org/wiki/RAID

    RAID (/ r eɪ d /; redundant array of inexpensive disks or redundant array of independent disks) [1] [2] is a data storage virtualization technology that combines multiple physical data storage components into one or more logical units for the purposes of data redundancy, performance improvement, or both.

  5. Non-standard RAID levels - Wikipedia

    en.wikipedia.org/wiki/Non-standard_RAID_levels

    The four-drive example is identical to a standard RAID 1+0 array, while the three-drive example is a software implementation of RAID 1E. The two-drive example is equivalent to RAID 1. [13] The driver also supports a "far" layout, in which all the drives are divided into f sections. All the chunks are repeated in each section but are switched in ...

  6. Parity drive - Wikipedia

    en.wikipedia.org/wiki/Parity_Drive

    A parity drive is a hard drive used in a RAID array to provide fault tolerance. For example, RAID 3 uses a parity drive to create a system that is both fault tolerant and, because of data striping, fast. [1] Basically, a single data bit is added to the end of a data block to ensure the number of bits in the message is either odd or even. [2]

  7. Data striping - Wikipedia

    en.wikipedia.org/wiki/Data_striping

    In other RAID configurations, such as a RAID 5 that contains distributed parity and provides redundancy, if one member drive fails the data can be restored using the other drives in the array. LVM2 Data striping can also be achieved with Linux's Logical Volume Management (LVM). The LVM system allows for the adjustment of coarseness of the ...

  8. mdadm - Wikipedia

    en.wikipedia.org/wiki/Mdadm

    RAID 1 – Mirror. RAID 4 – Like RAID 0, but with an extra device for the parity. RAID 5 – Like RAID 4, but with the parity distributed across all devices. RAID 6 – Like RAID 5, but with two parity segments per stripe. RAID 10 – Take a number of RAID 1 mirrorsets and stripe across them RAID 0 style.

  9. Disk array controller - Wikipedia

    en.wikipedia.org/wiki/Disk_array_controller

    Some other operating systems have implemented their own generic frameworks for interfacing with any RAID controller, and provide tools for monitoring RAID volume status, as well as facilitation of drive identification through LED blinking, alarm management, hot spare disk designations and data scrubbing § RAID from within the operating system ...