Ad
related to: metabolic acidosis serum
Search results
Results from the WOW.Com Content Network
Metabolic acidosis results in a reduced serum pH that is due to metabolic and not respiratory dysfunction. Typically the serum bicarbonate concentration will be <22 mEq/L, below the normal range of 22 to 29 mEq/L, the standard base will be more negative than -2 (base deficit) and the pCO 2 will be reduced as a result of hyperventilation in an ...
The anion gap is the quantity difference between cations (positively charged ions) and anions (negatively charged ions) in serum, plasma, or urine. The magnitude of this difference (i.e., "gap") in the serum is calculated to identify metabolic acidosis. If the gap is greater than normal, then high anion gap metabolic acidosis is diagnosed.
High anion gap metabolic acidosis is a form of metabolic acidosis characterized by a high anion gap (a medical value based on the concentrations of ions in a patient's serum). Metabolic acidosis occurs when the body produces too much acid , or when the kidneys are not removing enough acid from the body.
In general, the cause of a hyperchloremic metabolic acidosis is a loss of base, either a gastrointestinal loss or a renal loss [citation needed]. Gastrointestinal loss of bicarbonate (HCO − 3) [citation needed] Severe diarrhea (vomiting will tend to cause hypochloraemic alkalosis) Pancreatic fistula with loss of bicarbonate rich pancreatic fluid
metabolic acidosis, or respiratory alkalosis with renal compensation if too low (less than −2 mEq/L) Blood pH is determined by both a metabolic component, measured by base excess, and a respiratory component, measured by PaCO 2 (partial pressure of carbon dioxide). Often a disturbance in one triggers a partial compensation in the other.
Determining the cause of a metabolic acidosis that lacks a serum anion gap often depends on determining whether the kidney is appropriately excreting acid. The urine anion gap is an 'artificial' and calculated measure that is representative of the unmeasured ions in urine.
Ringer's lactate solution has a lower rate of acidosis as compared with normal saline. [1] [4] Use is generally safe in pregnancy and breastfeeding. [2] Ringer's lactate solution is in the crystalloid family of medications. [5] It is isotonic, i.e. it has the same tonicity as blood. [2]
If this gap falls within an acceptable range,(<10) then it is assumed that sodium, glucose, BUN are indeed the major dissolved ions and molecules in the serum. If, however, the calculated gap is above an acceptable range, then it is an indication that there is something else dissolved in the serum that is producing an osmol gap, which can be a ...
Ad
related to: metabolic acidosis serum