Search results
Results from the WOW.Com Content Network
Fluid-attenuated inversion recovery (FLAIR) is a magnetic resonance imaging sequence with an inversion recovery set to null fluids. For example, it can be used in brain imaging to suppress cerebrospinal fluid (CSF) effects on the image, so as to bring out the periventricular hyperintense lesions, such as multiple sclerosis (MS) plaques. [ 1 ]
An apparent diffusion coefficient (ADC) image, or an ADC map, is an MRI image that more specifically shows diffusion than conventional DWI, by eliminating the T2 weighting that is otherwise inherent to conventional DWI. [24] [25] ADC imaging does so by acquiring multiple conventional DWI images with different amounts of DWI weighting, and the ...
Fluid-attenuated inversion recovery (FLAIR) [2] is an inversion-recovery pulse sequence used to nullify the signal from fluids. For example, it can be used in brain imaging to suppress cerebrospinal fluid so as to bring out periventricular hyperintense lesions, such as multiple sclerosis plaques.
Functional MRI (fMRI) Blood-oxygen-level dependent imaging: BOLD: Changes in oxygen saturation-dependent magnetism of hemoglobin reflects tissue activity. [26] Localizing brain activity from performing an assigned task (e.g. talking, moving fingers) before surgery, also used in research of cognition. [27] Magnetic resonance angiography (MRA ...
An MRI pulse sequence in magnetic resonance imaging (MRI) is a particular setting of pulse sequences and pulsed field gradients, resulting in a particular image appearance. [ 1 ] A multiparametric MRI is a combination of two or more sequences, and/or including other specialized MRI configurations such as spectroscopy .
Planning began in 1986; [2] the data set of the male was completed in November 1994 and the one of the female in November 1995. The project can be viewed today at the NLM in Bethesda, Maryland. [3] There are currently efforts to repeat this project with higher resolution images but only with parts of the body instead of a cadaver.
The figure "Visualization of Medical Imaging" illustrates several types of visualization: 1. the display of cross-sections as gray scale images; 2. reformatted views of gray scale images (the sagittal view in this example has a different orientation than the original direction of the image acquisition; and 3. A 3D volume rendering of the same ...
Susceptibility weighted imaging (SWI), originally called BOLD venographic imaging, is an MRI sequence that is exquisitely sensitive to venous blood, hemorrhage and iron storage. SWI uses a fully flow compensated, long echo, gradient recalled echo (GRE) pulse sequence to acquire images.