enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Rating plate - Wikipedia

    en.wikipedia.org/wiki/Rating_plate

    The plate frequently contains the names of the machine and its manufacturer, so the rating plate is often called a name plate (hence the term "nameplate capacity" for a generator), although many devices carry separate nameplates and rating plates. [1] For an electric machine, the power rating is the number on its rating plate and corresponds to ...

  3. Nameplate capacity - Wikipedia

    en.wikipedia.org/wiki/Nameplate_capacity

    Nameplate capacity, also known as the rated capacity, nominal capacity, installed capacity, maximum effect or gross capacity, [1] is the intended full-load sustained output of a facility such as a power station, [2] [3] electric generator, a chemical plant, [4] fuel plant, mine, [5] metal refinery, [6] and many others.

  4. Capacity credit - Wikipedia

    en.wikipedia.org/wiki/Capacity_credit

    The capacity credit can be much lower than the capacity factor (CF): in a not very probable scenario, if the riskiest time for the power system is after sunset, the capacity credit for solar power without coupled energy storage is zero regardless of its CF [3] (under this scenario all existing conventional power plants would have to be retained after the solar installation is added).

  5. Power rating - Wikipedia

    en.wikipedia.org/wiki/Power_rating

    For every hour of operation at the service-factor-adjusted power rating, a motor loses two to three hours of life at nominal power, i.e. its service life is reduced to less than half for continued operation at this level. [4] [10] The service factor is defined in the ANSI/NEMA MG 1 standard, [11] and is generally used in the United States. [12]

  6. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    Capability curves for generators with full converters: D-shape (red), rectangular (green), triangular (blue) The inverter-based resources (like solar photovoltaic (PV) generators, doubly-fed induction generators and full-converter wind generators, also known as "Type 3" and "Type 4" turbines [5]) need to have reactive capabilities in order to contribute to the grid stability, yet their ...

  7. Diesel generator - Wikipedia

    en.wikipedia.org/wiki/Diesel_generator

    Generators must provide the anticipated power required reliably and without damage and this is achieved by the manufacturer giving one or more ratings to a specific generator set model. A specific model of a generator operated as a standby generator may only need to operate for a few hours per year, but the same model operated as a prime power ...

  8. Nominal power (photovoltaic) - Wikipedia

    en.wikipedia.org/wiki/Nominal_power_(photovoltaic)

    In the context of domestic PV installations, the kilowatt (symbol kW) is the most common unit for nominal power, for example P peak = 1 kW. Colloquial English sometimes conflates the quantity power and its unit by using the non-standard label watt-peak (symbol W p), possibly prefixed as in kilowatt-peak (kW p), megawatt-peak (MW p), etc.

  9. Load factor (electrical) - Wikipedia

    en.wikipedia.org/wiki/Load_factor_(electrical)

    In electrical engineering the load factor is defined as the average load divided by the peak load in a specified time period. [1] It is a measure of the utilization rate, or efficiency of electrical energy usage; a high load factor indicates that load is using the electric system more efficiently, whereas consumers or generators that underutilize the electric distribution will have a low load ...