In electrical distribution, a fuse cutout or cut-out fuse (often referred to as a cutout) is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads. An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to ...
In electrical engineering, IEC 60269 is a set of technical standards for low-voltage power fuses. [1] The standard is in four volumes, which describe general requirements, fuses for industrial and commercial applications, fuses for residential applications, and fuses to protect semiconductor devices.
The standard specifies breaking time versus current characteristics only for 3 A or 13 A fuses. For 3 A fuses: 0.02–80 s at 9 A, < 0.1 s at 20 A and < 0.03 s at 30 A. For 13 A fuses: 1–400 s at 30 A, 0.1–20 s at 50 A and 0.01–0.2 s at 100 A.
On a 3-phase circuit, a recloser is more beneficial than three separate fuse cutouts. For example, on a wye to delta conversion, when cutouts are used on the wye side and only 1 out of 3 of the cutout fuses open, some customers on the delta side have a low voltage condition, due to voltage transfer through the transformer windings. Low voltage ...
An assortment of thermal fuses. A thermal cutoff is an electrical safety device (either a thermal fuse or thermal switch) that interrupts electric current when heated to a specific temperature. These devices may be for one-time use (a thermal fuse), or may be reset manually or automatically (a thermal switch).
DIN 43700, was the specification by the Deutsches Institut für Normung for nominal front- and cut-out dimensions of measurement and control instruments for panel mounting. It has now been superseded by DIN IEC 61554:2002-08.
1 and q G 2 are the two electric charges, and r is the distance between the charges. This serves to define charge as a quantity in the Gaussian system. The statcoulomb is defined such that if two electric charges of 1 statC each and have a separation of 1 cm, the force of mutual electrical repulsion is 1 dyne. [1] Substituting F = 1 dyn, q G 1 ...
The failure of a neutral fuse would cut off power flow through the affected circuit, but the hot conductor could still remain hot relative to ground, an unexpected and potentially hazardous situation. Because of the presence of a neutral fuse, and in the event that it blew, the neutral conductor could not be relied on to remain near ground ...