Historically, roof pitch was designated in two other ways: A ratio of the ridge height to the width of the building (span) [6] and as a ratio of the rafter length to the width of the building. [7] Commonly used roof pitches were given names such as: Greek: the ridge height is 1 ⁄ 9 to 1 ⁄ 7 the span (an angle of 12.5° to 16°);
The following stair dimensions are important: The rise height or rise of each step is measured from the top of one tread to the next. It is not the physical height of the riser; the latter excludes the thickness of the tread. A person using the stairs would move this distance vertically for each step taken. The tread depth of a step is measured ...
Floor plans use standard symbols to indicate features such as doors. This symbol shows the location of the door in a wall and which way the door opens. A floor plan is not a top view or bird's-eye view ; it is a measured drawing to scale of the layout of a floor in a building.
An architectural drawing or architect's drawing is a technical drawing of a building (or building project) that falls within the definition of architecture.Architectural drawings are used by architects and others for a number of purposes: to develop a design idea into a coherent proposal, to communicate ideas and concepts, to convince clients of the merits of a design, to assist a building ...
Typically, a small British single garage is 8 by 16 feet (2.4 m × 4.9 m), a medium single garage is 9 by 18 feet (2.7 m × 5.5 m), and a large single garage is 10 by 20 feet (3.0 m × 6.1 m). Family sedans have become bigger than they were in the past, so the larger size has become a preferred option.
A stairwell or stair room is a room in a building where a stair is located, and is used to connect walkways between floors so that one can move in height. [1] Collectively, a set of stairs and a stairwell is referred to as a staircase or stairway .
Hong Kong law Chapter 123F, Building (Planning) Regulations, Regulation 23 sect 3 sub-paragraph (a) defined that: Subject to sub-paragraph (b), for the purposes of regulations 19, 20, 21 and 22, the gross floor area of a building shall be the area contained within the external walls of the building measured at each floor level (including any floor below the level of the ground), together with ...
[5] [3] As a rule of thumb, the depth should be 1 ⁄ 24 of the span. [5] The width of the ribs is typically 130 mm (5 in) to 150 mm (6 in), and ribs usually have steel rod reinforcements. [5] The distance between ribs is typically 915 mm (3 ft). [3] The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3]