Search results
Results from the WOW.Com Content Network
Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.
In electronics, a continuity test is the checking of an electric circuit to see if current flows (that it is in fact a complete circuit). A continuity test is performed by placing a small voltage (wired in series with an LED or noise-producing component such as a piezoelectric speaker ) across the chosen path.
All mass flow controllers have an inlet port, an outlet port, a mass flow sensor and a proportional control valve. The MFC is fitted with a closed loop control system which is given an input signal by the operator (or an external circuit/computer) that it compares to the value from the mass flow sensor and adjusts the proportional valve ...
The most common method for delivering test data from chip inputs to internal circuits under test (CUTs, for short), and observing their outputs, is called scan-design. In scan-design, registers ( flip-flops or latches) in the design are connected in one or more scan chains , which are used to gain access to internal nodes of the chip.
The test piece is attached in series with the pump and measuring element and air is pumped through the whole system. Therefore, all the air passing through the metering element also passes through the test piece. Because the volumetric flow rate through the metering element is known and the flow through the test piece is the same, it is also known.
The direction control valve is used to control the direction of flow of compressed air. They are usually classified into normally open (NO) and normally closed (NC) valves. The normally open valves will permit flow from the inlet port of the valve to the outlet port, normally the flow will be cut by changing the position of the valve.
This depth is converted to a flow rate according to a theoretical formula of the form = where is the flow rate, is a constant, is the water level, and is an exponent which varies with the device used; or it is converted according to empirically derived level/flow data points (a "flow curve"). The flow rate can then be integrated over time into ...
Automatic test equipment diagnostics is the part of an ATE test that determines the faulty components. ATE tests perform two basic functions. The first is to test whether or not the Device Under Test is working correctly. The second is when the DUT is not working correctly, to diagnose the reason.