Having a distinct connector designated for dimmable power also helps prevent confusion of dimmed and non-dimmed circuits which could lead to equipment damage. Even the smallest stage pin connectors are rated for 20 A, which translates to 2.4 kW at 120 V, compared to the 15 A and 1.8 kW of the NEMA 5-15.
The addition is a 3 ⁄ 16-inch (4.8 mm) diameter round or U-shaped ground pin, 1 ⁄ 8 in (3.2 mm) longer than the power blades (so the device is grounded before the power is connected) and located from them by 1 ⁄ 4 in (6.4 mm) edge-to-edge or 15 ⁄ 32 in (11.9 mm) center-to-center.
For power circuits, the color-coding uses the same colors as residential construction, and adds the additional wires used for three-phase systems. Black, Red and Blue are used for hot wires and White is used as the neutral wire in a 120/208 V circuit. Brown, Orange and Yellow are used as hot wires and gray is used as the neutral wire in a 277/ ...
An automotive wiring diagram, showing useful information such as crimp connection locations and wire colors. These details may not be so easily found on a more schematic drawing. A wiring diagram is a simplified conventional pictorial representation of an electrical circuit. It shows the components of the circuit as simplified shapes, and the ...
Wire crossover symbols for circuit diagrams. The CAD symbol for insulated crossing wires is the same as the older, non-CAD symbol for non-insulated crossing wires. To avoid confusion, the wire "jump" (semi-circle) symbol for insulated wires in non-CAD schematics is recommended (as opposed to using the CAD-style symbol for no connection), so as to avoid confusion with the original, older style ...
It has an earthing pin and two flat current-carrying pins forming an inverted V-shape (120°). The flat pins for the 10 A version measure 6.25 by 1.55 mm (0.246 by 0.061 in) and 8.0 by 1.9 mm (0.315 by 0.075 in) for the 20 A version, and are set at 30° to the vertical at a nominal pitch of 7.92 mm (0.312 in).
The IET Wiring Regulations permit an unlimited number of 13A socket outlets (at any point unfused single or double, or any number fused) to be installed on a ring circuit, provided that the floor area served does not exceed 100 m 2. In practice, most small and medium houses have one ring circuit per storey, with larger premises having more.
AS/NZS 3112 compliant plugs have two flat pins forming an inverted V-shape plus a vertical earthing pin. The flat blades measure 6.35 by 1.6 mm (1 ⁄ 4 by 1 ⁄ 16 in) with the active (line) and neutral pins 17.35 mm (11 ⁄ 16 in) long set 30° to the vertical and the vertical earth pin being 20 mm (0.787 in) in length. [15]