When the well has been drilled, it is completed to provide an interface with the reservoir rock and a tubular conduit for the well fluids. The surface pressure control is provided by a Christmas tree, which is installed on top of the wellhead, with isolation valves and choke equipment to control the flow of well fluids during production.
A tube well is a type of water well in which a long, 100–200 millimetres (3.9–7.9 in)-wide, stainless steel tube or pipe is bored underground. The lower end is fitted with a strainer, and a pump lifts water for irrigation. The required depth of the well depends on the depth of the water table.
Oil well Christmas tree. In petroleum and natural gas extraction, a Christmas tree, or tree, is an assembly of valves, casing spools, and fittings used to regulate the flow of pipes in an oil well, gas well, water injection well, water disposal well, gas injection well, condensate well, and other types of well.
Although the flow rate for a water well pumpjack is lower than that from a jet pump and the lifted water is not pressurised, the beam pumping unit has the option of hand pumping in an emergency, by hand-rotating the pumpjack cam to its lowest position, and attaching a manual handle to the top of the wellhead rod.
Gas lift well: gas is fed into valves installed in mandrels in the tubing strip. The hydrostatic head is lowered and the fluid is gas lifted to the surface. Single-well alternate completions: in this instance there is a well with two zones. In order to produce from both the zones are isolated with packers.
The valves required for oil and gas separators are oil discharge control valve, water-discharge control valve (three-phase operation), drain valves, block valves, pressure relief valves, and emergency shutdown valves (ESD). ESD valves typically stay in open position for months or years awaiting a command signal to operate.
Because certain combinations of check valve failure and/or system backpressure cause the relief valve to discharge, the device must be mounted in a location where the drain will not become flooded. An example of where backflow would harm the water supply is the use of well washing devices inside underground sewerage pumping stations.
An example of a water distribution system: a pumping station, a water tower, water mains, fire hydrants, and service lines [1] [2]. A water distribution system is a part of water supply network with components that carry potable water from a centralized treatment plant or wells to consumers to satisfy residential, commercial, industrial and fire fighting requirements.