Air flow in fume hood demonstrated by dry ice fog. A fume hood is typically a large piece of equipment enclosing six sides of a work area (including a movable sash window or door), the bottom of which is most commonly located at a standing work height (at least 28 to 34 inches (71 to 86 cm) above the floor).
Fume hoods are recommended to have an average inward velocity of 80–100 feet per minute (fpm) at the face of the hood. For higher toxicity materials, a higher face velocity of 100–120 fpm is recommended in order to provide better protection.
Note: the duct gas velocity is chosen to minimize duct dust dropout. Cement and lime plant duct velocity at normal operations is 3000 to 3200 foot per minute, lead plant velocities are 4000 to 4500 foot per minute, as the dust is heavier. Other industries, such as grain have lower gas velocities.
Fume hoods were introduced about 100 years ago to safeguard personnel working with hazardous materials. While many changes and improvements have been made, the basic concept and design of fume hoods remains the same. Air is drawn from the workplace, around the worker and into the front of the hood, and is then exhausted out of the laboratory.
Ducts for air pollution control in a 17000 standard cubic feet per minute regenerative thermal oxidizer (RTO). A round galvanized steel duct connecting to a typical diffuser Fire-resistance rated mechanical shaft with HVAC sheet metal ducting and copper piping, as well as "HOW" (Head-Of-Wall) joint between top of concrete block wall and underside of concrete slab, firestopped with ceramic ...
In kitchen ventilation systems, or for laboratory fume hoods, the design of effective effluent capture can be more important than the bulk amount of ventilation in a space. More generally, the way that an air distribution system causes ventilation to flow into and out of a space impacts the ability of a particular ventilation rate to remove ...
AMCA was formed in 1955 from several earlier trade associations which could be tracked back to the fan-testing requirements of the US Navy in 1923. It is a nonprofit organization that issues over 60 publications and standards, including testing methods, a Certified Ratings Program (CRP), application guides, educational texts, and safety guides.
Smoke exhaust ductwork, in Europe, is typically protected via passive fire protection means, subject to fire testing (typically to NBN EN 1366-8 [1]) and listing and approval use and compliance.