enow.com Web Search

  1. Ad

    related to: dedicated outside air system design calculations

Search results

  1. Results from the WOW.Com Content Network
  2. Dedicated outdoor air system - Wikipedia

    en.wikipedia.org/wiki/Dedicated_outdoor_air_system

    DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...

  3. Displacement ventilation - Wikipedia

    en.wikipedia.org/wiki/Displacement_ventilation

    The density difference between cold air and warm air creates upward convective flows known as thermal plumes. Instead of working as a stand-alone system in interior space, displacement ventilation system can also be coupled with other cooling and heating sources, such as radiant chilled ceilings [ 4 ] or baseboard heating.

  4. Moisture removal efficiency - Wikipedia

    en.wikipedia.org/wiki/Moisture_removal_efficiency

    DOAS Diagram. Moisture Removal Efficiency (MRE) is a measure of the energy efficiency of any dehumidification process. Moisture removal efficiency is the water vapor removed from air at a defined inlet air temperature and humidity, divided by the total energy consumed by the dehumidification equipment during the same time period, including all fan and pump energy needed to move air and fluids ...

  5. Stack effect - Wikipedia

    en.wikipedia.org/wiki/Stack_effect

    There is a pressure difference between the outside air and the air inside the building caused by the difference in temperature between the outside air and the inside air. That pressure difference ( ΔP ) is the driving force for the stack effect and it can be calculated with the equations presented below.

  6. Demand controlled ventilation - Wikipedia

    en.wikipedia.org/wiki/Demand_controlled_ventilation

    Standard HVAC system design uses fixed airflow rates to calculate the outdoor air (OA) required in a space. These airflow rates are determined by mechanical code and vary based on expected occupancy and space use. [2] This process of supplying fixed airflow to a space ensures that sufficient OA is present in that space when it is occupied.

  7. Air Movement and Control Association - Wikipedia

    en.wikipedia.org/wiki/Air_Movement_and_Control...

    It applies to a fan or other air moving device when air is used as the test gas with the following exceptions: (a) air circulating fans (ceiling fans, desk fans); (b) positive pressure ventilators; (c) compressors with inter-stage cooling; (d) positive displacement machines; (e) test procedures to be used for design, production, or field testing.

  8. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...

  9. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    An HVAC component that uses outside air, under suitable climate conditions, to reduce required mechanical cooling. When the outside air’s enthalpy is less than the required supply air during a call for cooling, an economizer allows a building’s mechanical ventilation system to use up to the maximum amount of outside air. enthalpy

  1. Ad

    related to: dedicated outside air system design calculations