Search results
Results from the WOW.Com Content Network
Pulsed Nd:YAG and Er:YAG lasers are used in laser tattoo removal and laser range finders among other applications. Pulsed lasers are also used in soft-tissue surgery. When a laser beam comes into contact with soft-tissue, one important factor is to not overheat surrounding tissue, so necrosis can be prevented. [ 3 ]
Using this equation, the minimum pulse duration can be calculated consistent with the measured laser spectral width. For the HeNe laser with a 1.5 GHz bandwidth, the shortest Gaussian pulse consistent with this spectral width is around 300 picoseconds; for the 128 THz bandwidth Ti:sapphire laser, this spectral width corresponds to a pulse of ...
The PRF is normally much lower than the frequency. For instance, a typical World War II radar like the Type 7 GCI radar had a basic carrier frequency of 209 MHz (209 million cycles per second) and a PRF of 300 or 500 pulses per second. A related measure is the pulse width, the amount of time the transmitter is turned on during each pulse.
For example, a system with a 3 GHz carrier frequency and a pulse width of 1 μs will have a carrier period of approximately 333 ps. Each transmitted pulse will contain about 3000 carrier cycles and the velocity and range ambiguity values for such a system would be:
These two lower-frequency beams are called the "signal" and "idler", respectively. This light emission is based on the nonlinear optical principle. The photon of an incident laser pulse (pump) is, by a nonlinear optical crystal, divided into two lower-energy photons. The wavelengths of the signal and the idler are determined by the phase ...
The frequency content of the generated ultrasound is partially determined by the frequency content of the laser pulses with shorter pulses giving higher frequencies. For very high frequency generation (up to 100sGHz) femtosecond lasers are used often in a pump-probe configuration with the detection system (see picosecond ultrasonics ).
For a Gaussian time profile, the autocorrelation width is longer than the width of the intensity, and it is 1.54 longer in the case of a hyperbolic secant squared (sech 2) pulse. This numerical factor, which depends on the shape of the pulse, is sometimes called the deconvolution factor. If this factor is known, or assumed, the time duration ...
The duty cycle expresses the pulse width as a fraction or percentage of one complete cycle. Pulse width is an important measure in radar systems. Radars transmit pulses of radio frequency energy out of an antenna and then listen for their reflection off of target objects. The amount of energy that is returned to the radar receiver is a function ...