enow.com Web Search

  1. Ad

    related to: grounding bonding conductor size chart

Search results

  1. Results from the WOW.Com Content Network
  2. TIA-607-B - Wikipedia

    en.wikipedia.org/wiki/TIA-607-B

    Among TIA-607-B's list of metallic components in need of bonding are racks, enclosures, ladders, surge protectors, cable trays, routers, switches and patch panels. Following the bonding of telecom infrastructure components, the entire system must be bonded to the building's main ground, which is sometimes also referred to as a grounding ...

  3. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    Equipment bonding conductors or equipment ground conductors (EGC) provide a low-impedance path between normally non-current-carrying metallic parts of equipment and one of the conductors of that electrical system's source. If any exposed metal part should become energized (fault), such as by a frayed or damaged insulator, it creates a short ...

  4. IEC 60364 - Wikipedia

    en.wikipedia.org/wiki/IEC_60364

    Section 54: Earthing arrangements, protective conductors and protective bonding conductors Section 55: Other equipment (Note: Some national standards provide an individual document for each chapter of this section, i.e. 551 Low-voltage generating sets, 557 Auxiliary circuits, 559 Luminaires and lighting installations)

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    This type of cable is the least expensive for a given size and is appropriate for dry indoor applications. The designation NM XX-Y indicates, respectively, the type of sheathing (in this case, non-metallic), the size of the main conductors, and the total number of circuit conductors (exclusive of the grounding conductor). For example, NM 14-2 ...

  6. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    While the national wiring regulations for buildings of many countries follow the IEC 60364 terminology, in North America (United States and Canada), the term "equipment grounding conductor" refers to equipment grounds and ground wires on branch circuits, and "grounding electrode conductor" is used for conductors bonding an earth/ground rod ...

  7. Bonding jumper - Wikipedia

    en.wikipedia.org/wiki/Bonding_jumper

    [2] Some codes require a bonding jumper to be pulled into non-metallic conduit or in electrical metallic tubing that may be exposed to corrosion or mechanical damage. In North American electrical codes, an important bonding jumper is found in main electrical panels, where the system neutral conductor is connected to earth ground. This must be ...

  8. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    Current flowing in a grounding conductor will produce a voltage drop along the conductor, and grounding systems seek to ensure this voltage does not reach unsafe levels. In the TN-S system, separate neutral and protective earth conductors are installed between the equipment and the source of supply (generator or electric utility transformer).

  9. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    Some types of metal conduit may also serve as a useful bonding conductor for grounding (earthing), but wiring regulations may also dictate workmanship standards or supplemental means of grounding for certain types. While metal conduit may sometimes be used as a grounding conductor, the circuit length is limited. For example, a long run of ...

  1. Ad

    related to: grounding bonding conductor size chart