Search results
Results from the WOW.Com Content Network
ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...
[4] [7] ASHRAE 90.1 follows a similar path of development and revision. [6] Though ASHRAE 90.1 is revised and published every three years just like the IECC, people can submit interim revisions at any time within this period. [5] ASHRAE has a standards committee that manages the process, and votes on the final versions of the energy code. [5]
In addition to tables published by ASHRAE for select latitudes, a computer program called CLTDTAB, available since 1993, can be used to generate custom CLTD/CLF/SCL tables for a specific zone type for any latitude and month. This allows the use of this method, without interpolation, for any area in the world.
ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]
Members of ASHRAE receive the current volume, in both print and CD-ROM form, each year as a basic membership benefit. An enhanced electronic version, known as ASHRAE Handbook Online is a web-based version updated annually that contains the four latest volumes as well as extra content such as calculations, demonstration videos, and spreadsheets ...
Space By Space Method. A defined list of many possible space types within a building the associated watts per square foot allowance. For example, ANSI/ASHRAE/IESNA Standard 90.1-2007 allows the Emergency Space of a hospital to be designed for 2.7 watts per square foot, but the Recovery areas of a hospital would be allowed 0.8 watts per square foot.
Building performance simulation model with input and some resulting output. Building performance simulation (BPS) is the replication of aspects of building performance using a computer-based, mathematical model created on the basis of fundamental physical principles and sound engineering practice.
DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...