A thermal switch (sometimes thermal reset or thermal cutout (TCO)) is a device which normally opens at a high temperature (often with a faint "plink" sound) and re-closes when the temperature drops. The thermal switch may be a bimetallic strip, often encased in a tubular glass bulb to protect it from dust or short circuit. Another common design ...
Murphy oil pressure gauges with switches that activate on low pressure. A pressure switch is a form of switch that operates an electrical contact when a certain set fluid pressure has been reached on its input. The switch may be designed to make contact either on pressure rise or on pressure fall.
A simple electric heating element warms the air.; When the thermostat calls for heat, blower and element come on at the same time. When thermostat is "satisfied", blower and element shut off.
Low-water cutoff: It is a mechanical means (usually a float switch) or an electrode with a safety switch that is used to turn off the burner or shut off fuel to the boiler to prevent it from running once the water goes below a certain point. If a boiler is "dry-fired" (burned without water in it) it can cause rupture or catastrophic failure.
After the control of air flow and temperature was standardized, the use of electromechanical relays in ladder logic to switch dampers became standardized. Eventually, the relays became electronic switches, as transistors eventually could handle greater current loads. By 1985, pneumatic controls could no longer compete with this new technology ...
A manifold pressure regulating shut-off valve (MPRSOV) restricts the flow as necessary to maintain the desired pressure for downstream systems. A certain minimum supply pressure is needed to drive the air through the system, but it is desired to use as low a supply pressure as possible, because the energy the engine uses to compress the bleed ...
The life of a filter may be assessed by monitoring the pressure drop through the filter medium at design air volume flow rate. This may be done by means of a visual display using a pressure gauge, or by a pressure switch linked to an alarm point on the building control system.
This damper can switch the electrical power to control additional "slave" dampers, minimizing the electrical load on the damper's control circuitry and power transformer A zone damper (also known as a Volume Control Damper or VCD ) is a specific type of damper used to control the flow of air in an HVAC heating or cooling system.