Search results
Results from the WOW.Com Content Network
As an example, the DQZ transform is often used in order to simplify the analysis of three-phase synchronous machines or to simplify calculations for the control of three-phase inverters. In analysis of three-phase synchronous machines, the transformation transfers three-phase stator and rotor quantities into a single rotating reference frame to ...
In either case, the output waveforms are phase shifted to obtain a 12-step waveform. If additional inverters are combined, an 18-step inverter is obtained with three inverters etc. Although inverters are usually combined for the purpose of achieving increased voltage or current ratings, the quality of the waveform is improved as well.
The transform applied to three-phase currents, as used by Edith Clarke, is [2] = = [] [() ()]where () is a generic three-phase current sequence and () is the corresponding current sequence given by the transformation .
FIGURE 5: Three-phase voltage source inverter circuit schematic FIGURE 6: Three-phase square-wave operation a) Switch state S1 b) Switch state S3 c) S1 output d) S3 output. Single-phase VSIs are used primarily for low power range applications, while three-phase VSIs cover both medium and high power range applications. [17]
A soft-switching three-level inverter (S3L inverter) is a high-efficiency power electronic inverter intended, in particular, for use with three-phase drives, as a grid-tie inverter for photovoltaic installations or wind turbines and in power supplies. [1] The topology was developed in 2009 at HTWG Konstanz (Constance University of Applied ...
A three-phase induction motor has a simple design, inherently high starting torque and high efficiency. Such motors are applied in industry for many applications. A three-phase motor is more compact and less costly than a single-phase motor of the same voltage class and rating, and single-phase AC motors above 10 hp (7.5 kW) are uncommon. Three ...
For example, balanced two-phase power can be obtained from a three-phase network by using two specially constructed transformers, with taps at 50% and 86.6% of the primary voltage. This Scott T connection produces a true two-phase system with 90° time difference between the phases.
Fig. 2: Top and bottom views of an air-cooled 10kW-Vienna Rectifier (400kHz PWM). The Vienna Rectifier is useful wherever six-switch converters are used for achieving sinusoidal mains current and controlled output voltage, when no energy feedback from the load into the mains is available.