Search results
Results from the WOW.Com Content Network
Modalities applied to measurement of ejection fraction is an emerging field of medical mathematics and subsequent computational applications. The first common measurement method is echocardiography, [7] [8] although cardiac magnetic resonance imaging (MRI), [8] [9] cardiac computed tomography, [8] [9] ventriculography and nuclear medicine (gated SPECT and radionuclide angiography) [8] [10 ...
The images obtained with echocardiography are in reference to the heart itself. Two key axes of the heart are the long axis and short axis. The long axis is an imaginary line from the apex of the heart through the center of the tricuspid/mitral valve (depending on ventricle of reference).
The left atrial volume is commonly measured by echocardiography or magnetic resonance tomography.It is calculated from biplane recordings with the equation: = where A4c and A2c denote LA areas in 4- and 2-chamber views respectively, and L corresponds to the shortest long-axis length measured in either views.
Sonographer doing an echocardiogram of a child Echocardiogram in the parasternal long-axis view, showing a measurement of the heart's left ventricle. Health societies recommend the use of echocardiography for initial diagnosis when a change in the patient's clinical status occurs and when new data from an echocardiogram would result in the physician changing the patient's care. [7]
Published normal ranges for LVMi are 49–115 g/m 2 for men and 43–95 g/m 2 for women. [ 1 ] [ 4 ] left ventricular hypertrophy (LVH) is defined as an abnormal increase in LVM, an important independent risk factor for cardiovascular morbidity and mortality.
Cardiac index is a critical parameter in evaluating cardiac performance and the adequacy of tissue perfusion. In healthy adults, the normal range of cardiac index is generally between 2.6 to 4.2 L/min/m². Values below this range may indicate hypoperfusion and are often seen in conditions such as heart failure, hypovolemia, and cardiogenic shock.
There are many ways to calculate the valve area of aortic stenosis. The most commonly used methods involve measurements taken during echocardiography. For interpretation of these values, the area is generally divided by the body surface area, to arrive at the patient's optimal aortic valve orifice area.
The standard definition of a reference range for a particular measurement is defined as the interval between which 95% of values of a reference population fall into, in such a way that 2.5% of the time a value will be less than the lower limit of this interval, and 2.5% of the time it will be larger than the upper limit of this interval, whatever the distribution of these values.