Search results
Results from the WOW.Com Content Network
>6.5 cm: 6 to 6.5 cm <6 cm 3: Mallampati: I or II: III: IV 4: Neck movement > 90° 80 to 90° < 80° 5: Underbite: Can protrude jaw: Cannot protrude jaw: 6: Body weight < 90 kg: 90 to 110 kg > 110 kg 7: Previous intubation history: No difficulty: Unsure or Unknown: Known difficulty Score ≥ 4 - Predictor of difficult intubation
Cricoid pressure, also known as the Sellick manoeuvre or Sellick maneuver, is a technique used in endotracheal intubation to try to reduce the risk of regurgitation.The technique involves the application of pressure to the cricoid cartilage at the neck, thus occluding the esophagus which passes directly behind it.
A more detailed and rapid neurological evaluation is performed at the end of the primary survey. This establishes the patient's level of consciousness, pupil size and reaction, lateralizing signs, and spinal cord injury level. The Glasgow Coma Scale is a quick method to determine the level of consciousness, and is predictive of patient outcome ...
While Mallampati classes I and II are associated with relatively easy intubation, classes III and IV are associated with increased difficulty. A systematic review of 42 studies, with 34,513 participants, found that the modified Mallampati score is a good predictor of difficult direct laryngoscopy and intubation, but poor at predicting difficult ...
Nasogastric intubation is a medical process involving the insertion of a plastic tube (nasogastric tube or NG tube) through the nose, down the esophagus, and down into the stomach. Orogastric intubation is a similar process involving the insertion of a plastic tube (orogastric tube) through the mouth. [1] Abraham Louis Levin invented the NG tube.
The laryngeal tube is also recommended for medical personnel not experienced in tracheal intubation, and as a rescue device when intubation has failed in adults. [16] According to the manufacturer the use of Laryngeal tubes is contraindicated in people with an intact gag reflex , known oesophageal disease , and people who have ingested caustic ...
Bag valve mask. Part 1 is the flexible mask to seal over the patients face, part 2 has a filter and valve to prevent backflow into the bag (prevents patient deprivation and bag contamination) and part 3 is the soft bag element which is squeezed to expel air to the patient
For human use, tubes range in size from 2 to 10.5 mm in internal diameter (ID). The size is chosen based on the patient's body size, with the smaller sizes being used for pediatric and neonatal patients. Tubes larger than 6 mm ID usually have an inflatable cuff. Originally made from red rubber, most modern tubes are made from polyvinyl chloride ...