enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Variable shunt reactor - Wikipedia

    en.wikipedia.org/wiki/Variable_shunt_reactor

    A traditional shunt reactor has a fixed rating and is either connected to the power line all the time or switched in and out depending on the load. Recently [1] variable shunt reactors (VSRs) have been developed and introduced on the market. The rating of a VSR can be changed in steps: the maximum regulation range depends on the capability of ...

  3. Switchyard reactor - Wikipedia

    en.wikipedia.org/wiki/Switchyard_reactor

    Shunt reactors are used in power systems to counteract the effect of the line parasitic capacitance, thereby stabilizing the system voltage within acceptable limits. [1] The utility of shunt reactors for voltage control on lightly-loaded transmission lines was examined in a 1926 paper presented at the AIEE by Edith Clarke . [ 2 ]

  4. File:UK Ground Position Light Signal - Shunt Signal - Aspect ...

    en.wikipedia.org/wiki/File:UK_Ground_Position...

    English: Chart shows the difference between 'on' and 'off' shunt ahead signal aspects. All of these are available as separate files below: File:UK Ground Position Light Signal - Shunt Signal - On - Pre-1996.svg; File:UK Ground Position Light Signal - Shunt Signal - On.svg; File:UK Ground Position Light Signal - Shunt Signal - Off.svg

  5. Voltage regulator - Wikipedia

    en.wikipedia.org/wiki/Voltage_regulator

    The power supply is designed to only supply a maximum amount of current that is within the safe operating capability of the shunt regulating device. If the stabilizer must provide more power, the shunt output is only used to provide the standard voltage reference for the electronic device, known as the voltage stabilizer.

  6. Magnetically controlled shunt reactor - Wikipedia

    en.wikipedia.org/wiki/Magnetically_Controlled...

    A magnetically-controlled shunt reactor (MCSR, CSR) represents electrotechnical equipment purposed for compensation of reactive power and stabilization of voltage level in high voltage (HV) electric networks rated for voltage classes 36 – 750 kV. MCSR is shunt-type static device with smooth regulation by means of inductive reactance.

  7. Smith chart - Wikipedia

    en.wikipedia.org/wiki/Smith_chart

    Using the Smith chart, the normalised impedance may be obtained with appreciable accuracy by plotting the point representing the reflection coefficient treating the Smith chart as a polar diagram and then reading its value directly using the characteristic Smith chart scaling. This technique is a graphical alternative to substituting the values ...

  8. Current limiting reactor - Wikipedia

    en.wikipedia.org/wiki/Current_limiting_reactor

    A current limiting reactor is used when the prospective short-circuit current in a distribution or transmission system is calculated to exceed the interrupting rating of the associated switchgear. The inductive reactance is chosen to be low enough for an acceptable voltage drop during normal operation, but high enough to restrict a short ...

  9. Talk:Variable shunt reactor - Wikipedia

    en.wikipedia.org/wiki/Talk:Variable_shunt_reactor

    Help; Learn to edit; Community portal; Recent changes; Upload file; Special pages