As transformer oil deteriorates through aging and moisture ingress, transformer oil should, depending on economics, transformer duty and other factors, be tested periodically. [5] Electric utility companies have a vested interest in periodic oil testing because transformers represent a large proportion of their total assets.
Dissolved gas analysis (DGA) is an examination of electrical transformer oil contaminants. [1] Insulating materials within electrical equipment liberate gases as they slowly break down over time. The composition and distribution of these dissolved gases are indicators of the effects of deterioration, such as pyrolysis or partial discharge , and ...
Transformer oil or insulating oil is an oil that is stable at high temperatures and has excellent electrical insulating properties. It is used in oil-filled wet transformers, [ 1 ] some types of high-voltage capacitors , fluorescent lamp ballasts , and some types of high-voltage switches and circuit breakers.
Oil sampling is a procedure for collecting a volume of fluid from lubricated or hydraulic machinery for the purpose of oil analysis. Much like collecting forensic evidence at a crime scene, when collecting an oil sample, it is important to ensure that procedures are used to minimize disturbance of the sample during and after the sampling process.
Thermal modelling – The useful life of a transformer is partially determined by the ability of the transformer to dissipate its internally generated heat to its surroundings. [3] The comparison of actual and predicted operating temperatures can provide a sensitive diagnosis of the transformer condition and might indicate abnormal operation.
Machines in this category include the steam or gas turbines in a power plant, crude oil export pumps on an oil rig or the cracker in an oil refinery. With critical machinery being at the heart of the process it is seen to require full on-line condition monitoring to continually record as much data from the machine as possible regardless of cost ...
A short in the coil creates a closed circuit that will act like the secondary coil of a transformer, with the growler acting like the primary coil. This will induce an alternating current in the shorted armature that will in turn cause an alternating magnetic field to encircle the shorted armature coil. A flat, broad, flexible piece of metal ...
Sweep frequency response analysis (SFRA) is a method to evaluate the mechanical integrity of core, windings and clamping structures within power transformers by measuring their electrical transfer functions over a wide frequency range.