Search results
Results from the WOW.Com Content Network
A fire test can be conducted to determine the degree of flammability. Test standards used to make this determination but are not limited to the following: Underwriters Laboratories UL 94 Flammability Testing; International Electrotechnical Commission IEC 60707, 60695-11-10 and 60695-11-20; International Organization for Standardization ISO 9772 ...
This test method measures flame growth on the underside of a horizontal test specimen, using the Steiner tunnel test. The result is derivation of a Flame Spread Index ( FSI ), [ 2 ] which is a non-dimensional number which is placed on a relative scale in which asbestos-cement board has a value of 0, and red oak wood has 100.
Fire test in Sweden, showing rapid fire spread through burning of cable jackets from one cable tray to another. A fire test is a means of determining whether fire protection products meet minimum performance criteria as set out in a building code or other applicable legislation.
In the U.S. the most common method of measuring LFLs and UFLs is ASTM E681. [26] This standard test is required for HAZMAT Class 2 Gases and for determining refrigerant flammability classifications. This standard uses visual observations of flame propagation in 5 or 12 L spherical glass vessels to measure the flammability limits.
Mixed Flowing Gas (MFG) test is a laboratory test in which the temperature (°C), relative humidity (%RH), concentration of gaseous pollutants (in parts per billion, ppb or parts per million ppm level), and other critical variables (such as volume exchange rate and airflow rate) are carefully defined, monitored and controlled.
A flame test involves introducing a sample of the element or compound to a hot, non-luminous flame and observing the color of the flame that results. [4] The compound can be made into a paste with concentrated hydrochloric acid, as metal halides , being volatile, give better results. [ 5 ]
A tracer-gas leak testing method is a nondestructive testing method that detects gas leaks.A variety of methods with different sensitivities exist. Tracer-gas leak testing is used in the petrochemical industry, the automotive industry, the construction industry [1] and in the manufacture of semiconductors, among other uses.
Flammability diagrams show the control of flammability in mixtures of fuel, oxygen and an inert gas, typically nitrogen. Mixtures of the three gasses are usually depicted in a triangular diagram, known as a ternary plot .